POINTS TO BE CONSIDERED BEFORE INSTALLATION OF THE DEVICE

Water treatment system’s operating water tempe-

rature is between minimum 5˚C (41˚F) and maxi-

mum 40˚C (104˚F). It has risk of freezing to operate 

the device below 5˚C as it carries risk of damage to 

filters when operated at above 40˚C.
It is necessary to select a suitable location first for 

installation of water treatment device. It must be 

considered during selection that installation place 

should be close to cold water line of the RO device 

and to the drainage and sufficient space should be 

left for working in case of malfunction and filter 

replacement.
Water treatment device is designed for water with 

specifications close to tap water, whose inlet con-

ductivity is max. 600 ppm and the turbidity is max 

3 NTU. If raw water source and specifications are 

unknown, the raw water should be sent for analysis 

before installation of the device in order to check 

the suitability.

If the device is used beyond the limit values men-

tioned in technical specification part of the users’ 

manual, the requested quality will not be achieved 

for product water. Usage of such feed water will 

cause variation in replacement periods of filters 

and membrane.
Inlet pressure is between 3 - 6 bar for water treat-

ment devices without pump and between 1 - 6 bar 

for water treatment devices with pump. The opti-

mum working pressure is 3 bar. In case the inlet 

pressure is above 4 bar, it is recommended to ins-

tall a pressure reducer to prevent more wastewa-

ter discharge. Do not connect the device to power 

socket before it is installed.Our company will not be 

liable for any problems caused by non-observance 

of the above warnings.

TREATMENT DEVICE FLOW SCHEME

1. PRE-FILTER
2.  FIRST CARBON
3.  SEDIMENT FILTER / CTO
4.  R.O (50-100 GPD)

5.  SECOND CARBON
6.  RAW WATER
7. PUMP
8. WASTEWATER

9.  STORAGE TANK
10. PRESSURE REDUCER
11. FAUCET

WATER SUPPLY

FAUCET

TANK

Summary of Contents for ENJOY COOL

Page 1: ...COMMERCIAL DOMESTIC RO COMMERCIAL DOMESTIC RO ENJOY COOL PALLAS MANUAL ...

Page 2: ...you to lead a healthy life The product is manufactured in modern facilities without giving no harm to environment It is recommended that you read the manual very carefully before using the product which is manufactured studiously in Important information and recommendations about using device Warnings against dangers of safety of life and property Electric shock warning Risk of fire Hot surface wa...

Page 3: ...ON OF THE DEVICE 6 BOX CONTENTS AND ASSEMBLY PARTS 7 DEVICE PROPERTIES 8 INSTALLATION AND ASSEMBLY 9 MAINTENANCE AND CLEANING 11 START UP AFTER MAINTENANCE 14 WARRANTY CONDITIONS 15 IMPORTANT SAFETY AND ENVIRONMENTAL INSTRUCTIONS CONSUMER RIGHTS 16 TROUBLESHOOTING 17 FREQUENTLY ASKED QUESTIONS 18 AUTHORIZED SERVICES AND SPARE PARTS SUPPLIERS 18 ...

Page 4: ...is systemrequires va rious technical knowledge and experience such as product water quality raw water analysis type of membrane etc Reverse osmosis practices Water treatment device is designed to work with minimum water pressure It does not require che mical use and produces quality water It is manu factured as a compact device that can easily be installed anywhere thanks to minimum dimensions RO ...

Page 5: ... rein forced with a pump feed water passes through the following filtrations respectively 1st Stage 5 micron pp sediment filter The pre sediment filter retains suspended materials and particles in the water and protects succes sive filtrations especially the membrane filter 1 mm 1000 micron 2nd Stage Activated carbon filter removes pol lutants which are harmful to human health and membrane filter ...

Page 6: ... water should be sent for analysis before installation of the device in order to check the suitability If the device is used beyond the limit values men tioned in technical specification part of the users manual the requested quality will not be achieved for product water Usage of such feed water will cause variation in replacement periods of filters and membrane Inlet pressure is between 3 6 bar ...

Page 7: ...cron Spun Sediment Filter 7 75 GPD Membrane 8 3 2 Gallon Storage Tank 9 Metal Ball Valve 1 4 10 75 GPD Dynamic Pump available in model with pump 11 24 Volt 1 5 Amper Adapter available in model with pump 12 Feed water connection part 13 Automatic shut off valve 14 Tube 15 Users Manual and Warranty Certificate MANUAL BOX CONTENTS AND ASSEMBLY PARTS 1 5 9 2 6 10 14 13 11 12 3 7 4 8 ...

Page 8: ... 5 C Max Operating Water Temperature 40 C 40 C Min Inlet Pressure 100 000 pascals 300 000 pascals Max Inlet Pressure 600 000 pascals 600 000 pascals Max Inlet TDS ppm 500 ppm 500 ppm Inlet Diameter 6 mm 6 mm NOTE TheequipmentsusedintheproductareincompliancewithWaterQuality CEandNSFstandards Theequipmentsarecertified ...

Page 9: ...FIGURE A 3 FIGURE A 2 FIGURE A 4 FIGURE A 5 3 way adapter 3 way adapter Closed 1 4 Ball Valve Open WATER INTAKE IN UNDER COUNTER DOUBLE BATTERY WATER INTAKE 3 way adapter 1 4 Ball Valve SINGLE BATTERY WATER INTAKE 3 way adapter Extension 1 4 Ball Valve 1 In case of drilling countertop or sink faucet for clean water must be installed carefully in terms of usage and aesthetics You can start to drill...

Page 10: ...o the faucet after mounting the faucet and drain line Loosen and pull out stem nut on outlet of the post carbon filter Put the nut on tube and tighten firmly Insert the other side of the tube into res pectively yellow nut and collet placed under the faucet Push the tube to the faucet and tighten the nut firmly HOSE CONNECTION SCHEME As shown in figure A Water inlet B Product water tube is connecte...

Page 11: ...ethepurifiedwaterforcooking preparingtea coffeeetc Incaseofwaterleaks brokenfiltersetc turnoffthevalve ofwatersupplyandcorrectthefaults IMPORTANT 12 5 Micron Spun Sediment Filter It should be replaced approximately every 6 months depending on the water contamination 12 GAC Carbon Cartridge Filter UDF If the water is clear and the total amount of chlorine is low the cartridge life is 6 months on av...

Page 12: ...rench Finally place the union at the water inlet side of the membrane properly and tighten firmly 1 Open the tube union of 3rd housing and dischar ge the water supplied to Sedimentfilter Activa ted Carbon filter and BlockCarbon filter Perform washing for 10 minutes 2 First three filters are washed If post carbonand mains pressure are present mineral filter iswas hed with the mains pressure for 10 ...

Page 13: ...ll pressure reducer on water inlet of RO device when installation pres sure is high Ensure that periodical maintenan ce is performed on time and by the authorized service In case of long periods of non use turn off water supply Follow start up procedure when you want to re operate Keep your device clean by wiping with a wet clo th periodically and avoid using harsh and corro sive cleaners Water Tr...

Page 14: ... from a higher place Pay attention to keep the parts in the same place to avoid losing them Keep the device in a dry and closed place Pay attention not to drop break shake crush the device during transportation and handling Ensure that it does not get damaged due to heat humidity or dust Keep it out of sun exposure You can get support from our authorized services to avoid unexpected damages during...

Page 15: ...ulting from replace ment or damage of electrical cable connections Damages or defects resulting from paint or stain on any part of the product Damages or defects due to sticking any label on the device Damages or defects due to natural disasters Damages or defects resulting from running the device with water below 5oC degrees and above 40oC degrees Damages or defects due to electric networks Damag...

Page 16: ...nsumer may apply to the consumer arbit ration board or the consumer court where the consumer resides in or the products have been purchased for the disputes that may arise in connection with the exercise of the rights arising from the warranty RIGHT OF CHOICE PROVIDED TO CONSUMER WITH 11th ARTICLE OF LAW 1 If the product is found defective Consumer can renege on the contract by notif ying the sell...

Page 17: ...RE IS WASTE WATER FLOW Too low or high pressure Pump should be used for water with low pressure as pressure reducer is recommended for water with high pressure Faulty check valve Replace check valve LEAKS IN DEVICE Faulty connection Check all connections Not properly cut edges of tubes Remove leaking tubes cut the edges straightly and replace them Not properly fitted gaskets Fit the gaskets UNPLEA...

Page 18: ...d Less usage of the system affects only replacement period of membrane Can I assemble the device and replace filtersmyself Yes you can However any other practise not per formed by a service provider will cause the war ranty to be voided If the service is provided by an authorised personnel the device will continue to be under warranty till the expiration date of warranty Contact the seller dealer ...

Page 19: ... date of delivery to an authorised service if warranty has already expired In case of not being repaired within 10 workdays the manufacturer or importer must supply a similar product to the consumer until the product is repaired In the event that the product is defected within warranty perion the days when the product remains in the service are added to warranty period 6 Defects resulting from con...

Page 20: ...KETI Address Antalya Organize Sanayi Bölgesi 1 Kısım Antalya Bulvarı No 36 07190 Döşemealtı ANTALYA TURKEY TEL 0 242 417 76 20 E MAIL esli esli com tr Product ENJOY COOL Models LUX WITH PUMP CLASS WITH PUMP Conformity Assessment Method 2014 35 EU Applicable CE Directives 2014 35 EU Applicable International Technical Standards EN 60730 2 15 2010 A11 2011 TS EN 60335 1 TS EN 60335 1 AC TS EN 60335 1...

Reviews: