UH219

UH219 Series

H I G H   P R E S S U R E   F I LT E R S

s e r v i c e  

i n s t r u c t i o n s

7.4

Lubricate element O-ring with clean system fluid. 
Reinstall element in the shell assembly. Lightly lubricate 
cover-to-head or tube-to-head (as applicable) O-ring with 
clean system fluid and reassemble the housing until thread
bottoms. The cover or tube should be torque tightened
using a suitable socket wrench to 74 ft/lb or 100Nm. 
O-ring sealing is not improved by over tightening

7.5

Bleed the system and check for leaks as per section 4.8.

7.6

After element change ENSURE DIFFERENTIAL
PRESSURE DEVICE IS RESET BY PUSHING IN THE
RED BUTTON; electrical switches reset automatically.
When system reaches normal operating temperature,
check that the electrical switch has not actuated and/or
the visual warning button has remained depressed. 
If visual indicator rises due to a cold start condition,
reset again as per section 6.

8

Warranty, Limitation of Liability and
Remedies

THERE IS NO WARRANTY OF MERCHANTABILITY OR
FITNESS FOR ANY PARTICULAR PURPOSE WITH RESPECT
TO ANY OF THE PRODUCTS, NOR IS THERE ANY OTHER
WARRANTY EXPRESS OR IMPLIED, EXCEPT AS PROVIDED
FOR HEREIN.
For a period of twelve months from the date of delivery from
Seller or three thousand hours of use, whichever occurs first
(the "Warranty Period"), Seller warrants that products
manufactured by Seller when properly installed and
maintained, and operated at ratings, specifications and 
design conditions, will be free from defects in material and
workmanship. By way of explanation and not limitation, the
Seller does not warrant the service life of the filter element 
as this is beyond the Seller's control and depends upon the
condition of the system into which the filter is installed.

4

7

Filter element installation / servicing

During servicing, the external surfaces of the filter assembly
must be cleaned to remove any dust deposits.
Servicing must be conducted using suitable tools that do not
present a hazard.
Servicing must not be carried out when a potentially explosive
atmosphere is present.

Refer to Service Parts List (Section 9) for item numbers for
applicable replacement element series. Remove and replace
element as follows:
7.1 

Turn off and depressurize the system. 

7.1.1  For UH219C series (cover service):

Open the vent plug (7) at the top of the filter one and 
one-half turns. Open partially the blanking plug (6b) in 
the filter head and drain fluid into a suitable waste 
receptacle. This sequence may be long for high viscosity
fluids. Replace and torque tighten the blanking plug 
to 38 ft/lb or 54Nm. Unscrew and remove cover (3) from 
tube (2) counter-clockwise when viewed from above. 
It will be necessary to use a 1" socket wrench on the 
hexagon on the cover (3) to loosen the cover initially.

Note: The UH219C series assembly is equipped with Pall’s
'Auto-Pull' element extraction mechanism to facilitate element
removal. While removing the cap, tabs on the element endcap
lock into hooks in the cap and the element is automatically
pulled from the nipple.

7.1.2  For UH219H series (head service):

Open the drain plug (7) at the bottom of the bowl 
assembly (tube and cover) and drain fluid from the bowl 
into a suitable waste receptacle. Replace and torque 
tighten drain plug to 12 ft/lb or 16Nm. Unscrew and 
remove the bowl assembly (2 and 3) from head (1)
counter-clockwise when viewed from below. It will be
necessary to use a 1" socket wrench on the hexagon on
the cover (3) to loosen the cover initially.

7.2

Element replacement (UE219 Series): Remove filter 
element (8), if already fitted, and carefully inspect the 
interior surface (flow through the element is in-to-out) 
for visible contamination. Normally no dirt should show, 
but visible dirt or particles can be an early warning of 
system component failure. Discard both the filter 
element and its O-ring. The filter element is NOT 
CLEANABLE. Any attempt to clean the filter element 
can cause degradation of the filter medium and allow 
contaminated fluid to pass through the filter element.

7.3

DO NOT run the system without a filter element 
installed. For UH219C series: check that the O-ring (4) 
between the cover (3) and tube (2) is not damaged. 
For UH219H series: check that the O-ring (5) between 
the tube (2) and head (1) is not damaged. 
Use the replacement filter as indicated by the part 
number on the element endcap.

WARNING:
FAILURE TO DEPRESSURISE THE FILTER BEFORE
SERVICING ELEMENT COULD RESULT IN
EXPLOSIVE LOSS OF FLUID, DAMAGE TO
EQUIPMENT AND POSSIBLE PERSONAL INJURY.

WARNING:
DO NOT ATTEMPT TO CLEAN OR RE-USE THE
ELEMENT.
ONLY USE GENUINE PALL REPLACEMENT FILTER
ELEMENTS. USE OF SUBSTITUTE ELEMENTS MAY
INVALIDATE PRODUCT WARRANTY.

CAUTION:
Filter elements should be replaced upon indication or
at specified intervals, six months maximum. Failure to
change the element will cause the filter to go on
bypass.

Summary of Contents for UH219 Series

Page 1: ...UH219 UH219 Series service instructions UK 60908 IMSIUH219 EN UH219 Service Instructions ENGLISH ...

Page 2: ...required for element removal is as follows 4 2 1 UH219C series cover service 102mm 4in for length 4 203mm 8in for length 8 338mm 13 3in for length 13 and 508mm 20in for length 20 housings 4 2 2 UH219H series head service 100mm 3 9 for all lengths 4 2 3 The UH219 Housing is supplied without a filter element For element installation and servicing procedures refer to Section 7 4 3 Threaded differenti...

Page 3: ...abels 6 Differential pressure devices Reference should be made to product literature for dimensions operating parameters part numbering ordering information and specifications 6 1 Differential pressure devices actuate when the element needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start red button extends 5mm 3 ...

Page 4: ...the filter one and one half turns Open partially the blanking plug 6b in the filter head and drain fluid into a suitable waste receptacle This sequence may be long for high viscosity fluids Replace and torque tighten the blanking plug to 38 ft lb or 54Nm Unscrew and remove cover 3 from tube 2 counter clockwise when viewed from above It will be necessary to use a 1 socket wrench on the hexagon on t...

Page 5: ...ltered outside of the Seller s factory except by Seller or Seller s authorized distributor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration accident or negligence in u...

Page 6: ...UH219 UH219 Series HIGH PRESSURE FILTERS s e r v i c e instructions 6 2 4 8 6b 3 1 Figure 2 5 7 6 Inlet Not shown on this diagram Not shown on this diagram ...

Page 7: ...AA 4 täyskierteistä reikää syvyys AA 4 trous taraudés de profondeur AA 4 fori completamente filettati profondità AA 4 tapgaten met draad over volle diepte 4st fästhål Gänga Z Min gängdjup AA GG Q Flange Connection Details Flange Code Nominal Tube Size GG Q Z Thread AA E16 1 1 093 2 250 7 16 14 UNC 0 87 G16 1 27 8 mm 57 2 mm M12 x 1 75 22 mm E20 11 4 1 250 2 625 1 2 13 UNC 0 75 G20 11 4 31 8 mm 66 ...

Page 8: ...2008 Printed in England IMSIUH219 Visit us on the web at www pall com Pall Corporation has offices and plants throughout the world in locations including Argentina Australia Austria Belgium Brazil Canada China France Germany India Indonesia Ireland Italy Japan Korea Malaysia Mexico the Netherlands New Zealand Norway Poland Puerto Rico Russia Singapore South Africa Spain Sweden Switzerland Taiwan T...

Reviews: