020-17469-00 Instructions For Use Jet Mixer RevD
13
5. Installation and use of the mixing biocontainer
5.1 Installing the mixing biocontainer
Remove the mixing biocontainer from the packaging bags.
Insert the drain tubing through the opening in the bottom plate of the tank.
If the tubing is too large to fit through the hole, or if the tubing has large items such as y-
pieces or filters, the small drain cover plate around the drain hole can be removed.
If the mixing biocontainer incorporates an EZ Drain fitment, position it in the drain port
cutout, install the drain insert plate, and then snap the EZ Drain clip over the fitment
OUTSIDE the tank (Figure 17).
Figure 17: EZ Drain clip installation
Confirm that the drain is fully closed by sliding the locking collar up until it clicks, then pulling
down firmly on the blue BarbLock®* to close the drain, and sliding the locking collar down
again to lock it (Figure 18).