![Palazzetti L1 Installation Instructions, Use And Maintenance Download Page 33](http://html1.mh-extra.com/html/palazzetti/l1/l1_installation-instructions-use-and-maintenance_747767033.webp)
ENGLISH
Technical Data
P1
P2
P3
P5
Primary
hydraulic circuit
Max capacity (L/h)
2000
1600
1800
1800
Max temperature (°C)
95 - 110 peak
Max pressure (bar)
6
Residual prevalence at 1000 L/h (m.c.a.)
6.5
6
6
6
Liquid
Water + 30% glicol max
Hydraulic heating
circuit
Max capacity (L/h)
1700
1800
1800
1600
Max temperature (°C)
95 - 110 peak
Max pressure (bar)
6
Non return valve opening P
ǻ
p: 2kPa (200 mm.c.a.)
Residual prevalence at 1000 L/h (m.c.a.)
5.4
/
6
5
Liquid
Water + 30% glicol max
Electrical
specifications
Supply voltage
230 V/50Hz
Max power absorption (W)
60
30
100
100
Protection rating IP
IPX0D
Mechanical
specifications
Plate heat exchanger (plates no.)
40
20
40/20
40
Connections generator side
FAST
Connections system side
FAST
Connections centre distance (mm)
60
External sizes (cm)
45x50x16
70x50x16
45x50x16
Weight (kg)
13.5
13.0
20.0
14.5
Technical Data
L1
L2
L3
L5
Primary
hydraulic circuit
Max capacity (L/h)
2000
1600
1800
1800
Max temperature (°C)
95 - 110 peak
Max pressure (bar)
6
Residual prevalence at 1000 L/h (m.c.a.)
6.5
6
6
6
Liquid
Water + 30% glicol max
Hydraulic heating
circuit
Max capacity (L/h)
1700
1800
1800
1600
Max temperature (°C)
95 - 110 peak
Max pressure (bar)
6
Non return valve opening P
ǻ
p: 2kPa (200 mm.c.a.)
Residual prevalence at 1000 L/h (m.c.a.)
5.4
/
6
5
Liquid
Water + 30% glicol max
Electrical
specifications
Supply voltage
230 V/50Hz
Max power absorption (W)
110
90
160
160
Protection rating IP
IPX0D
Mechanical
specifications
Plate heat exchanger (plates no.)
40
20
40/20
40
Connections generator side
FAST
Connections system side
FAST
Connections centre distance (mm)
60
External sizes (cm)
45x50x16
70x50x16
45x50x16
Weight (kg)
15.0
14.0
22.0
16.0
33