25
cod. 004777080 MBL - 08/2018 - Palazzetti - PN - Italy
ENGLISH
Never use alcohol, petrol, kerosene or other liquid fuels to light the
¿
re. Keep these substances away from the
¿
re. Do not
use petrol or chemical origin
¿
re-lighters as they can seriously damage the walls of the
¿
rebox .
Only use ecological
¿
re lighting aids.
During operation, any
À
ammable materials must be placed at least 180 cm from the radiation area (glass surfaces)
3 COMBUSTION
CONTROL
Combustion is regulated by inserting the cold handle supplied in the adjustment lever situated at the base of the door (Fig. 6).
Turn it clockwise (-) or counter-clockwise (+) to have a greater
À
ow of combustion air corresponding to a greater combustion
À
ame
Turn the adjustment lever towards the + symbol to obtain faster combustion; turn it towards the - symbol to obtain slower
combustion; select the desired position (Pos. 1-2-3)
Positions 1-2-3 correspond to the certi
¿
ed power values.
4 FIREPLACE
MAINTENANCE
To be carried out at least once a year, or every 40 quintals of wood.
During the maintenance operation, the technician must:
• thoroughly
clean
the
À
ues (a diagram indicating the path of the exhaust smoke is attached in FIG. 7 and FIG. 8 (smoke
de
À
ectors dismantling sequence with O2 Ring). After cleaning, re
¿
t the de
À
ectors and the O2 Ring (if featured in the model
purchased) in reverse order.
• check the condition of all the seals and make sure they work properly
• check the condition of all internal components and make sure they are clean
• make sure the smoke outlet connection is sealed and clean
• make sure that the stove is working properly
5 INSPECTION AND MAINTENANCE SCHEDULE
EVERY
IGNITION
1
YEAR
(a)
Grate
X
Ash pan/compartment
X
Glass
X
Door seals *
X
Smoke exhaust duct*
X
([FKDQJHUDQGÀXH
X
(*)
By a specialised technician.
(a)
At least once a year or every 4 tonnes of burnt fuel.