6 ALARM
MANAGEMENT
The stove is supplied with an automatic status control
system. When a system anomaly is detected, an error
message is displayed on the control panel screen (
¿
g. 5.1
.
/LVWRIDODUPVDQGSRVVLEOHFDXVHV
CODE
(5525:$51,1*
DESCRIPTION
POSSIBLE CAUSES
E 0 0 4
NO CONNECTION
Communication error
The wire linking the motherboard and the control panel
has been interrupted or disconnected
E 1 0 1
NO IGNITION
Start-up failure
Hopper is empty
Pellet quality
Ignition system damaged
Dirty brazier
E 1 0 2
E
;
HAS.TEMP.
Temperature of fumes is too low
Possible ignition failure
Check the pellet level in the hopper and that brazier is
clean and in the correct position.
Check that the door and the ash box are properly closed.
E 1 0 3
E
;
HAUST FAN
Flue gas fan error
Flue gas fan is disconnected or faulty
E 1 0 4
BLACK OUT
Black-out
Power failure when the stove is operating.
E 1 0 5
WATER PROBE
Supply water probe alarm
Water probe disconnected or defective
E 1 0 6
RETURN PROBE
Return water probe alarm
Return water probe disconnected or defective
E 1 0 8
THERMAL
Safety error
Problems with the heating system
Problems with the pump
Problems with overheating in the pellet hopper
E 1 0 9
DEPRESS
Pressure error
Dirty
À
ue
Burn pot gaskets worn
Inadequate combustion air intake
E 1 1 0
ROOM PROBE
Temperature probe malfunction
Faulty air probe
E 1 1 1
SMOKE PROBE
Exhaust probe malfunction
Faulty exhaust temperature probe
E 1 1 3
BURN POT
BLOCK
Fault in the burn pot shaking system
Possible electromechanical component fault
$ODUPUHVHW
After you have checked the message type and resolved the problem, you can reset the warning by holding down
the ON button for a little while.
,QWKHHYHQWRIHUURUFRGH
E 1 0 8
UHDFWLYDWHWKHPDQXDOWKHUPRVWDWVORFDWHGDWWKHIURQWRIWKHXQLWEHIRUHUHVHWWLQJ
WKHDODUP¿J7HFKQLFDO$VVLVWDQFH&HQWUH
At this point you can restart the stove.