background image

 

2 OF 15 

 

 

 

1. GENERAL INFORMATION 

 
The purpose of this manual is to assist you in operating and maintaining your portable generator.   
Please read it carefully as it contains information which will help you achieve years of dependable, 
trouble-free operation. 

 

WARRANTY-PARTS-SERVICE 

    

To obtain prompt, efficient service, always remember to give the item number and serial number. 
Whenever you need parts or repair service, contact Princess Auto Ltd. at: 

 

Telephone # 

1-800-665-8685  

 

Fax # 

1-800-265-4212 

 

The generator is shipped on a pallet and requires no assembly before it can be used. The battery 
must be prepared for it’s initial use. Please refer to the battery instruction sheet included for details. 

 
 

2. SAFETY GUIDELINES 

 
DEFINITIONS 

Safety symbols identify important safety messages that alert to the possibility of personal injury or 
death. Review them carefully before operating this unit and before performing maintenance or 
repairs. Check the rules and regulations, at your operating site and Province or Territory, and identify 
possible hazards. The appropriate signal word for each message has been selected using the 
following guidelines: 

  - Danger indicates an immediate and specific hazard, which 

will

 result in 

severe 

personal

 

injury

 or 

death

 if the proper precautions are not taken. 

  - Warning indicates a specific hazard or unsafe practice, which 

could

 result in 

severe personal injury

 or 

death

 if proper precautions are not taken. 

  - 

Caution indicates potentially hazardous situation, which

 may 

result in

 minor or 

moderate injury 

or

 damage to unit 

if proper practices are not taken.  

 

IMPORTANT SAFETY INSTRUCTIONS  

 

 

  

Read and understand the operator’s manuals and all safety alerts before operating or 

maintaining your portable generator. Be certain that everyone operating this equipment is familiar 
with the recommended operating and maintenance procedures and follows all the safety precautions. 
Never let children or untrained adults operate this equipment.

 

 

 

This generator set produces electrical current. As such, safety guidelines must be followed. Improper 
use of this generator can result in electrocution, injury or death. Do not operate, service or repair this 
generator unless fully qualified to do so. 

 

This generator set is designed to be operated in dry conditions and in outdoor areas only. NEVER 
operate this generator in rain, snow, sleet or generally wet conditions. Damage to the generator, 
bodily injury, or death could result from electrocution. 

 

If this generator is connected to a building, home, business, or any other electrical circuit normally fed 
by utility power, steps must be taken to ensure the generator output and the utility power are 
positively isolated. Failure to isolate the utility and generator electrical systems will result in generator 
damage and could result in injury or death to utility workers due to the back-feed of electricity. 

 

Summary of Contents for 8251498

Page 1: ... Safety 4 2 2 Additional Safety Operational Guidelines 4 3 OPERATION 5 3 1 Generator Performance Specifications 5 3 2 Electrical Loads 6 3 3 Warning on Sensitive Equipment 6 3 4 Engine Limitations on Generator Performance 6 3 5 Power Receptacles 7 3 6 Circuit Breaker 8 3 7 Automatic Idle Control 8 3 8 LCD Amperage Hour Readout 9 3 9 12VDC Battery 9 3 10 Starting the Generator 10 4 MAINTENANCE 10 5...

Page 2: ...practice which could result in severe personal injury or death if proper precautions are not taken Caution indicates potentially hazardous situation which may result in minor or moderate injury or damage to unit if proper practices are not taken IMPORTANT SAFETY INSTRUCTIONS Read and understand the operator s manuals and all safety alerts before operating or maintaining your portable generator Be ...

Page 3: ...spillage possibly causing a fire or an explosion Lubricating oil conforming to the engine manufacturer s specifications must be added to the proper level before operation Failure to fill the crankcase with lubricating oil will void all engine warranties Do not exceed the rated capacity of the generator The total electrical loads at each outlet must be added to determine the total electrical load T...

Page 4: ... mechanical and electrical condition Do not overload this generator Overloading this generator can cause generator damage powered apparatus damage and excessive heat build up Always keep hands body parts hair and clothing well away from the rotating or HOT parts of the generator set Exhaust systems can cause severe burns Do not start this generator with connected devices turned ON Always make sure...

Page 5: ...he extension cord s wire gauge is of sufficient size to minimize voltage drop Never handle extension cords or electrical circuits if standing in water or a damp area Operate service or fill with fluids on a level surface only Do not operate this generator in a corrosive or flammable environment Never clean this generator with high pressure water or a garden hose Water can accumulate within the gen...

Page 6: ...pressor 1 2 hp 1400 Light Bulb Bulb rated Air Compressor 3 4 hp 1800 Nail Gun 1200 Air Compressor 1 hp 2000 Microwave 750 Battery Charger 25A 600 Paint Sprayer 1 3 hp 650 Belt Sander 3 Belt 1000 Paint Sprayer hand air less 175 Circular Saw 6 825 1050 Radio 50 200 Coffee Maker 900 1100 Refrigerator 600 Lawn Edger 550 Table Saw 10 2000 Furnace Fan 1 3 hp 1200 Television 250 550 Hot Plate single 1500...

Page 7: ...d the generator rating Do not exceed the individual receptacle ratings as shown in Table 3 below Do not exceed the total generator ratings shown in Table 1 on page 5 RECEPTACLE 1 RECEPTACLE 2 20A 120V 20A 120 240V Table 3 Maximum Allowable Receptacle Current Draw RECEPTACLE 1 RECEPTACLE 2 BLACK FILLED LEADS ARE LIVE TERMINALS GREY LEADS ARE GROUND TERMINALS WHITE LEADS ARE NEUTRAL TERMINALS Figure...

Page 8: ...eaker by pushing the switch to the ON position NOTE ensure that it is safe to reset the switch after power has been cut off The tool appliance being used will operate immediately after the circuit breaker has been reset Use caution 3 7 AUTOMATIC IDLE CONTROL The generator is equipped with an automatic idle feature When activated this feature allows the engine to idle down when there is no power be...

Page 9: ...sed can be displayed anytime while the generator is running by pressing the black button labeled Amps Hrs Switch directly below the LCD Press the black button again to go back to reading amperage LCD AMP HOURS SWITCH LOW BATTERY WARNING LIGHT Figure 4 Amp Hour Readout 3 9 12VDC BATTERY Please refer to the battery instruction manual provided for battery installation and maintenance information The ...

Page 10: ...ould display the amperage being drawn from the generator 4 MAINTENANCE Engine Fuel Use Unleaded Gasoline ONLY Engine Oil Refer to the Engine s Operators Manual Engine Maintenance Refer to the Engine s Operators Manual regarding all engine maintenance issues Generator Cleaning ALWAYS shut off the generator and allow the generator to completely cool before performing cleaning operations DO NOT use h...

Page 11: ... pilot light lit cigarette water heater static discharge etc It is recommended that your generator be started and operated for several minutes at least every 30 days If the generator cannot be operated every 30 days follow the storage recommendations within the engine documentation NOTE A fuel shut off valve is positioned at the base of the fuel tank The valve should be closed during storage perio...

Page 12: ...12 OF 15 5 PARTS LIST ...

Page 13: ...13 OF 15 ...

Page 14: ...UT SPRING 10 24 U TYPE 045 062 6 25 BOLT HEX 250 20 UNC X 1 75 LG GR 5 PTD 2 26 NUT LOCK NYLON 25 20 UNC 5 27 BOLT HEX SRD FLANGE 250 20 X 50 LG 8 28 BOLT HEX SRD FLANGE 10 24 X 50 LG 6 29 SCREW HEX WASHER 10 24 X 50 LG THREAD CUTTING 7 30 NUT SPRING 250 20 U TYPE 11 31 WASHER EXTERNAL TOOTH LOCK 313 2 32 BOLT HEX SER 312 18UNC X 75 LG 2 33 NUT HEX SERRATED FLANGE 312 18 UNC 2 34 BOLT HEX SERRATED...

Page 15: ... 33 RED 1 64 NSM DECAL 1 65 2460048 FILTER FUEL INLINE 3 16 1 66 10001276 LINE FUEL 3 16 ASSY 1 67 NUT SPRING 10 24 U TYPE 025 040 2 68 8004211 BOLT J M5 X 216 ASSY 2 69 9161274 DECAL WARNING REFUEL 1 70 9160813 DECAL PAL SERIAL 1 71 BOLT HEX SRD 375 16 UNC 1 LG 4 72 ALTERNATOR ANCHOR ROD 1 73 WASHER PTD 281 ID X 625 OD 1 74 WASHER LOCK SPLIT REG 312 PTD 4 75 NUT HEX 250 20 UNC 1 76 BOLT HEX SERRA...