Wiring the HRE-450
150-450-105-02, Revision 02
8
November 4, 1998
HRE-450 List 5
Connect the HRE-450 to the signal cables and ground wire:
1
Loosen the compression connector nuts on the bottom of the HRE-450 using one of the following methods:
•
Using your hand, turn the compression connector nuts counterclockwise.
•
If the compression connector nuts are too tight to loosen by hand, use groove-joint pliers to hold each
cable fitting center locknut, then use groove-joint pliers to turn each compression nut counterclockwise.
Figure 5.
Bottom View of the HRE-450
2
Feed solid ground wire, up to #6 AWG, through the HRE-450 GND cable fitting.
3
Strip approximately 1/2 inch of insulation from the end of the ground wire.
4
Insert the stripped wire into the ground wire access, then tighten the ground wire connector.
5
Using your fingers, tighten the ground wire connector.
6
Remove the compression connector nut from the cable stub fitting.
7
Insert approximately 6 inches of interface telephone cable through the exposed cable stub fitting hub.
8
Slit the ends of the leads of each drop-wire pair and bend as shown in
Figure 6
.
Mounting bracket
Cable stub
Ground wire access
Compression connector nuts
Cable stub
Air vent/breather cap