MiniMaster

MA60-16E

ENGLISH

14. Operation information and troubleshooting

LED signals

Type of LED signal

Explanation

The two red LEDs come on with a steady light The unit is not calibrated - dosing is not possible

The two red LEDs flash alternately

Flow too high or too low – dosing shut off

All red and yellow LEDs flash at the same 

time

Time-Out function:

 

Dosing has taken place continuously for 90 mins – dosing shut off.

- Check dosing pump function and setting.

- Check that the chemical level in the drums is not too low.

- Check leakage/function of the dosing hoses, dosing points and dosing pumps.

- If the installation has a salt chlorinator: Check that the salt chlorinator is not

  shut off, that it is correctly set and that the signal cable between the chlori-

  nator and the MiniMaster is correctly connected.

Restart:

 First shut off the dosing (On/Off button E), wait a few seconds, 

then start dosing by pressing the On/Off button (E) again.

LED comes on with a steady light

lit for a long period - out for a shorter period

Dosing is activated, metering in progress

Flashing LED,

lit for a short period - out for a longer 

period

Dosing is not activated, but metering is in progress

Rolling LEDs

Forced dosing in progress

Chlorine unit only:

Flashing LEDs 3, 4, 5 after start sequence

Time-Out activated = dosing blocked after 90 minutes of continuous dosing, 

(factory set value)

Flashing LEDs 3, 4, 6 after start sequence

Time-Out deactivated (unlimited continuous dosing)

pH unit only:

Flashing LEDs 2, 4, 5 after start sequence

Alkali dosing activated

Flashing LEDs 2, 4, 6 after start sequence

Acid dosing activated

Troubleshooting

Type of fault

Action

Unit does not start

1. If the unit is interlocked over a shut down circulation pump, the unit will not 

start.

2. Check fuses on the circuit board.

Unstable/low flow in the fitting

Check/clean the pre-filter Clean and lubricate the adjuster screw on the fitting.

The unit cannot be calibrated

1. Low/high measurement water flow (chlorine unit only) - check filter.

2. Unreasonable measurement values; 

    free chlorine values < 0.3 ppm and > 3.0 ppm

    - check the chlorine values using photometric equipment

3. High levels of cyanuric acid in the pool water - check using photometric

    equipment.

    Dilute the pool water with tap water if necessary.

4. Electrode or connection fault - check connections, clean electrodes or

    replace them.

High and low values during operation

- calibrated value not stable.

Dosing set too high or too low. Adjust dosing based on pool volume and 

circulation speed.

Check that the water flow through the fitting is even.

Check the condition and connections of the electrodes.

Underpressure in return hose

Press the Flow button (F, see Figure 6), open the Adjuster Screw (H, see 

Figure 7) until the red LED (High) comes on. Then cut the flow using ball 

valve L2 (see Figure 1) carefully until the green LED (flow OK) comes on.

Reservations

We accept no liability for printing errors. We reserve the right to make changes to MiniMaster technical specifications or its manual.

Colour differences may occur due to technical factors in the printing process.

Summary of Contents for MiniMaster

Page 1: ...l n AB Box 728 SE 194 27 Upplands V sby Sweden Tel 46 8 594 110 50 Fax 46 8 590 868 80 e mail info pahlen se www pahlen com Manual User manual Manuel d utilisation Handboek MA60 16 rev 4 Swedish desig...

Page 2: ...er to maintain a balanced water quality it is important that you adhere to the recommended value detailed below pH values outside the recommended limits will provide misleading chlorine values in the...

Page 3: ...appropriate lengths and connect them without sharp bends between the Mini Master and pre filter A small piece of flexible hose may also be fitted to the measurement water outlet if required 6 Inlet A...

Page 4: ...f dosing module 230VAC NOT potential free R Phase for dosing of chlorine and pH augmenting agent R Phase for dosing of pH reducing agent RN Zero Neutral Common for dosing OC OC Transistor open collect...

Page 5: ...is low manually direct into the pool or using MiniMaster dosing modules accessories press button E to activate the dosing function press button G for 3 seconds for forced dosing for 30 seconds then pr...

Page 6: ...rement equipment and check that the free chlorine value is between 0 5 1mg l ppm 2 Calibrate the unit by simultaneously pressing the calibration buttons F G and keeping them pressed The LED will flash...

Page 7: ...t only 1 Switch off the power to the MiniMaster 2 Turn on the power 3 Press button E when LED 1 comes on and release when LED 2 comes on each LED flashes twice second 4 Press button E when LED 6 comes...

Page 8: ...t least once a year using silicon grease with PTFE non petroleum based grease Check hoses connections and chemical levels on a regular basis Electrodes Should be cleaned on a regular basis see instruc...

Page 9: ...ed continuous dosing pH unit only Flashing LEDs 2 4 5 after start sequence Alkali dosing activated Flashing LEDs 2 4 6 after start sequence Acid dosing activated Troubleshooting Type of fault Action U...