background image

11

MiniMaster

MA60-16E

ENGLISH

Th

is

 d

oc

um

en

t a

nd

 it

co

nt

en

ts

 a

re

 th

ex

cl

us

iv

pr

op

er

ty

 o

f P

ah

ns

 a

nd

 m

ay

 n

ot

 b

co

pi

ed

re

pr

od

uc

ed

, t

ra

ns

m

itt

ed

 o

r c

om

m

un

ic

at

ed

 to

 a

 th

ird

 

pa

rty

, o

r u

se

fo

r a

ny

 p

ur

po

se

 w

ith

ou

t w

rit

te

pe

rm

is

si

on

.

Art.no.

Rev.no.

Scale

Designed by:

Approved by:

Revised by:  Date

Drawn by:  Date

Drawing number

Assembly drawing no.

Surface treatment

part of ISO 2768-1 

The tolerance class in accordance with this

E

Box 728, SE-194 27 Upplands Väsby, Sweden

Phone +46 8 59411050, Fax +46 8 59086880

4166X0 se tabell

CRO 2010-09-01

ASA 2013-02-19

MiniMaster pH - Redox

MiniMaster pH - fritt klor

 

M11278 4

50

0

310

83

310

50

0

Sid 3.    Till MA60-16

85

310

310

500

500

1. Product description

MiniMaster is an electronic unit that monitors and controls the pH value and/or chlorine levels in a swimming pool. The pH value 

is measured using a pH electrode, whilst chlorine levels are measured using a free chlorine electrode.

MiniMaster can be connected to a dosing module for acid or alkali (pH) and chlorine.

The pack contains: 1 x control unit, 5 m PE hose, 1.5 m PVC hose, pre-filter and hose couplings.

The electrode kit is supplied separately, containing electrode(s), cleaning agent and, in the case of the pH model, also pH 7.3 
buffer solution.

2. Technical data

MiniMaster pH/chlorine MiniMaster chlorine

MiniMaster pH

Power consumption - excl. dosing module

4W

2W

2W

Power consumption - dosing module (max.)

2x100W

100W

100W

Rated current 

1 A

Voltage

220-240V 1~N 50/60Hz

Temperature range

0 to +45°C

Seal class

IP44

Dimensions L x W x H

310 x 85 x 500 mm

Weight

2 kg

3. General information

MiniMaster continuously measures and indicates the pH value and chlorine content of pool water.

Where values to not conform to specified limits, the control unit issues signals to an external dosing module that doses the water.

In order to maintain a balanced water quality, it is important that you adhere to the recommended value detailed below. pH values 

outside the recommended limits will provide misleading chlorine values in the MiniMaster.

If the pool water has previously been dosed with organic chlorine (e.g. in tablet/disc form), this may produce inaccurate chlorine 

measurements (for measures to correct this, see section 8, paragraph 7).

We recommend you use a photometric test instrument to obtain a reference measurement.

MiniMaster must be installed against a wall or similar, and must sit straight. It is recommended that MiniMaster is installed 

indoors or under cover, and is easily accessible in order to enable easy ready of values, allow servicing to be carried out, take 

water samples and clean the pre-filter.

Recommended values in respect of water quality

Chlorine content: 

0.5-1.0 mg/l (ppm)

pH value: 

7.2-7.6

Alkalinity: 

60-120 mg/l (ppm) 

Chloride (salt) content:  max 10 g/l (1%) 

Calcium hardness:   

100-300 mg/l (ppm) 

Cyanuric acid: 

max 5 ppm

For more details about pool chemistry and care, see the User’s Guide on our website http://www.pahlen.com/users-guide/

4. Safety

The MiniMaster supply voltage must be interlocked in parallel over the connection to the pool circulation pump. This is to ensure 

reliable supply and to protect against accidental dosing when the circulation pump is not in operation.

Dosing of chlorine, acid or similar substances shall be done after all other equipment in order to minimise the risk of corrosion.

Dosing points in the liquid acid and chlorine circulation system shall be positioned as far from each other as possible, but at least 

500 mm, and 

chlorine dosing must always be positioned last

, see Figure 4.

5. Dimensions

MiniMaster ph/chlorine 

MiniMaster chlorine or pH

Summary of Contents for MiniMaster

Page 1: ...l n AB Box 728 SE 194 27 Upplands V sby Sweden Tel 46 8 594 110 50 Fax 46 8 590 868 80 e mail info pahlen se www pahlen com Manual User manual Manuel d utilisation Handboek MA60 16 rev 4 Swedish desig...

Page 2: ...er to maintain a balanced water quality it is important that you adhere to the recommended value detailed below pH values outside the recommended limits will provide misleading chlorine values in the...

Page 3: ...appropriate lengths and connect them without sharp bends between the Mini Master and pre filter A small piece of flexible hose may also be fitted to the measurement water outlet if required 6 Inlet A...

Page 4: ...f dosing module 230VAC NOT potential free R Phase for dosing of chlorine and pH augmenting agent R Phase for dosing of pH reducing agent RN Zero Neutral Common for dosing OC OC Transistor open collect...

Page 5: ...is low manually direct into the pool or using MiniMaster dosing modules accessories press button E to activate the dosing function press button G for 3 seconds for forced dosing for 30 seconds then pr...

Page 6: ...rement equipment and check that the free chlorine value is between 0 5 1mg l ppm 2 Calibrate the unit by simultaneously pressing the calibration buttons F G and keeping them pressed The LED will flash...

Page 7: ...t only 1 Switch off the power to the MiniMaster 2 Turn on the power 3 Press button E when LED 1 comes on and release when LED 2 comes on each LED flashes twice second 4 Press button E when LED 6 comes...

Page 8: ...t least once a year using silicon grease with PTFE non petroleum based grease Check hoses connections and chemical levels on a regular basis Electrodes Should be cleaned on a regular basis see instruc...

Page 9: ...ed continuous dosing pH unit only Flashing LEDs 2 4 5 after start sequence Alkali dosing activated Flashing LEDs 2 4 6 after start sequence Acid dosing activated Troubleshooting Type of fault Action U...