V4-iPC chargers are fitted with a mains input socket conforming to
CEE22 (IEC socket). Mains supply connection to the charger should
be made using only the standard lead supplied with this equipment.

3.2

V4-iPC chargers have been designed for use on AC mains supplies
worldwide, and automatically accept supplies in the range 90V to
265V. Mains supply frequency must be in the range 50-60 Hz.

NOTE: V4-iPC chargers MUST NOT be operated from a vehicle 12V
battery using the PAG Vehicle Battery-Power Converter, Model No.
9774.

3.3

PAG TECHNICAL SALES AND INFORMATION DESK:
For further information, contact PAG Technical Sales and Information
Desk +44 (0)20 8543 3131 or your nearest PAG Authorised Service
Centre. Alternatively, visit the PAG Web Site at www.paguk.com.

4.1

IMPORTANT: Note section 4.16 Supply Failure. V4-iPC chargers may
be disconnected from the supply at any time in complete safety and
without damage to the charger or any batteries connected.

4.2

Connect the charger to a suitable supply using the standard lead.
The blue LCD screen will illuminate.

4.3

On power-up, the charger will automatically run a self test program.

4.4

With no batteries connected, the display will show ‘ABST’ on all four
channels.

4.5

When batteries are connected, charging will automatically commence
and the display will show ‘CHRG’ on the appropriate channels.

4.6

Li-Ion batteries are charged simultaneously, using PAG’s Intelligent
Parallel Charging program (see ‘Charging Times’ Section 2.17).
NOTE: Nickel-Metal Hydride batteries are charged sequentially.

Summary of Contents for V4-IPC

Page 1: ...Instruction Manual PAG V4 iPC Intelligent Parallel Charger...

Page 2: ...ected to any channel on the V4 iPC Charger Connection to the camera can be made using PAG Adaptor Model 9450 XLR 4 male to female coiled lead The V4 CPA outputs 16 8V at 5 5A and is suitable for use w...

Page 3: ...1 Instruction Manual CONTENTS SECTION PAGE 1 SAFETY 2 2 SPECIFICATION 3 3 INSTALLATION 5 4 OPERATING INSTRUCTIONS 5 5 SERVICING REPAIRS 7 6 WARRANTY 8 PAG V4 iPC Intelligent Parallel Charger...

Page 4: ...r use only To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture 1 7 Although the charger is short circuit protected extreme care should always be taken not to...

Page 5: ...re the output has been shut down Additionally the program detects batteries having a very low voltage and initiates a special low charge current The program will operate until the voltage has risen su...

Page 6: ...Complies with the following EU Directives EMC Directive 89 336 EU Low Voltage Directive 73 23 EU 2 14 Operating Temperature Range 0 C to 40 C 32 F to 104 F 2 15 Overall Dimensions 160mm high x 191mm w...

Page 7: ...Desk 44 0 20 8543 3131 or your nearest PAG Authorised Service Centre Alternatively visit the PAG Web Site at www paguk com 4 1 IMPORTANT Note section 4 16 Supply Failure V4 iPC chargers may be disconn...

Page 8: ...ies are charged in as short a time as possible 4 12 If the charger detects a faulty battery while the charging program is running the battery status will show FAIL This could be caused by one of sever...

Page 9: ...THE CORRECT RATING If the replacement of the fuse fails to correct the above symptoms do not attempt further fuse replacement It is likely that a fault has developed Seek advice from your nearest PAG...

Page 10: ...he warranty provided the warrantor s examination discloses to its satisfaction the product was defective The warrantor may at its option replace the product in lieu of repair With regard to any equipm...

Page 11: ...attery Charger MODEL 9700V APPLICABLE EU DIRECTIVES EMC DIRECTIVE 89 336 EU LOW VOLTAGE DIRECTIVE 73 23 EU CE MARKING DIRECTIVE 93 68 EU HARMONISED STANDARDS APPLIED GENERIC EN 50081 1 EMISSIONS EN 50...

Page 12: ...U5087 ISS A JAN 07 T 44 0 20 8543 3131 F 44 0 20 8540 4116 E sales paguk com www paguk com PAG Ltd 565 Kingston Road Raynes Park London SW20 8SA...

Reviews: