background image

INSTALLATION GUIDE

FFHL Series LED Flood

Instructions and specifi cations are subject to change at any time without notice.  Copyright© 2021 PacLights   All Rights Reserved 

Page 3 of 4

Need help?  (800) 988 -6386   Email:  [email protected]  Website:  www.PacLights.com 

PL_INST_FFHL_v0

The Arm Mount drilling template is for either a Square or Round 
pole (Fig. 10).  Drill holes on the Square pole by following the Drilling 
Template to mount the FFHL to the desired height (Fig. 11).

2

FIG. 10

The Arm Mount is available for all FFHL fi xtures (Fig. 9).  The Arm 
Mount can be mounted on either a Square or Round pole.

1

FIG. 9

SIDE PLATE

ARM MOUNT

 SCREWS

FFHL ARM MOUNT WITH FLOOD MOUNT

LOCKING PLATE

SQUARE POLE 
GASKET

ROUND POLE 
GASKET

WASHER

LOCK 
WASHER

SCREW

If the FFHL fi xture is being installed to a Square Pole, remove the 
Round Pole Gasket (Fig. 12).

3

FIG. 12

FIG. 11

SQUARE 
POLE 

ROUND POLE 
GASKET

ARM MOUNT

FIG. 13

FIG. 15

 SCREW

LOCKING 
PLATE

MOUNTING 
POLE

POWER CABLE

Run the Power Cable through the Pole.  Place the Locking Plate and 
Gasket inside the Mounting Pole and fasten the FFHL fi xture with 
the Arm Mount onto the Pole with the Cap Head Screws (Fig. 15).  
For the Round Pole, repeat Steps 2-4, except the remove the Square 
Pole Gasket for Step 3.  Reinstall the Side Plate (Refer to Fig. 13).

6

FIG. 14

FFHL CABLE

Before installing the Arm Mount remove the Trunnion Mount (Refer 
to Fig. 5).  Install the Flood Mount and the Fixture Mount (Refer to 
Fig. 6).  Run the FFHL Cable through the inside the Arm Mount.   
Align the hole and teeth from the Arm Mount with the FFHL Fixture 
Mount and use the Cap Head Screw to fasten them together at the 
desired fi xture tilt angle (Fig. 14).  Rotate the FFHL fi xture on the 
Flood Mount as needed (Refer to Fig. 4)  

5

FFHL FLOOD 
MOUNT

SCREW

Remove the Screws (4) and the Side Plate from the Arm Mount 
before installing the FFHL fi xture (Fig. 13).

4

ARM MOUNT

ARM MOUNT

FFHL FIXTURE

FIXTURE 
MOUNT

Summary of Contents for FFHL Series

Page 1: ...in power is OFF before installing or maintaining fixture No user serviceable parts inside To prevent wiring damage or abrasion do not expose wiring to edges of sharp objects CAUTION For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened firmly Apply weatherproof silicone sealant around the edge of the Back Box and or Junction Box This is especial...

Page 2: ...T WITH FLOOD MOUNT The Slipfitter Mount can be mounted on a Round Pole Ø2 3 8 Run the FFHL Cable from the FFHL fixture and the Slipfitter Mount to the Pole and follow the Wiring Diagram provided to properly install the light fixture to the Power Supply Cable Tighten the Slipfitter Screws 4 to secure the FFHL fixture to the Round Pole Fig 8 4 SLIPFITTER FFHL FIXTURE ROUND POLE POWER CABLE FFHL CABLE SCRE...

Page 3: ... 11 SQUARE POLE ROUND POLE GASKET ARM MOUNT FIG 13 FIG 15 SCREW LOCKING PLATE MOUNTING POLE POWER CABLE Run the Power Cable through the Pole Place the Locking Plate and Gasket inside the Mounting Pole and fasten the FFHL fixture with the Arm Mount onto the Pole with the Cap Head Screws Fig 15 For the Round Pole repeat Steps 2 4 except the remove the Square Pole Gasket for Step 3 Reinstall the Side ...

Page 4: ...econdary Surge Protector Remove the Screws 4 from the Cover of the Junction Box Remove the Knockout Plug s needed to install the Photocell Control or Secondary Surge Protector Fig 16 J BOX COVER SCREW 1 JUNCTION BOX KNOCKOUT PLUG Install the Cable Glands with fastener Nuts where the Knockout Plug s have been removed Install the Photocell Control with a Locknut The Secondary Surge Protector can be ...