background image

FALC Series LED Area Light

Installation Guide

Need help? Tech help line:

(800) 988-6386

Email:

[email protected]

Website:

www.paclights.com

Copyright © 2020 PacLights

All Rights Reserved

Note: Instructions are subject to change at any time without notice

02-00041-20423

AC-ALC-3M 3-in-1

Universal Mount

(as Trunnion Mount)

AC-ALC-3M 3-in-1

Universal Mount

(as Trunnion Mount)

Adjust the tilt angle on the FALC Fixture to the

desired location. Tighten the Socket Head Screws
with an wrench to keep the fixture in place.

Drill holes on the

Mounting Surface by
following the Drilling
Template to mount the
Trunnion Mount to the
desired height.

If the Power Supply Cable is coming from a Junction Box the

FALC Power Cable must be fed into a Junction Box specific for
outdoor applications.  Follow the wiring diagram provided to for
installation. All wiring must be done inside the J-box and must be
fed through a water-proof connector. All wiring must be installed
by a certified electrician and must be compliant to NEC standards.

Page 7 of 7

SIDE PLATE

SIDE

PLATE

GASKET

SCREWS

DRILLING
TEMPLATE

Run Power Supply
Cable through this
slot opening into
the Arm Mount

Ø 0.375” Clearance

holes on pole to align
with Locking Plate
hole locations

5.5”

6.25”

0.75”

0.77”

R.24”

Remove the [4] Flat-Head Machine Screws and the Side Plate before installing

onto the FALC Fixture.

If the Power Supply Cable

is coming from the wall, the Power
Supply Cable will run through the
center of the Trunnion Mount.
Fasten the Trunnion Mount to the
Mounting Surface using the
appropriate mounting Bolts
(not included).

Align the teeth of the FALC Bracket Mount

to the Trunnion Mount.  Use a wrench to fasten
the Socket Head Srew to the Trunnion Mount
and the FALC Bracket Mount. You can connect
the FALC Cable to the Power Supply without
using a Junction Box only if used with a weather
proof connector.

Once all wiring is properly installed fasten

the Side Plate and Gasket back to the
Trunnion Mount.

DRILL
HOLES/
SLOT

2

1

3

4

BOLTS

POWER
SUPPLY

CABLE

TRUNNION

MOUNT

MOUNTING

SURFACE

SCREW

TRUNNION

MOUNT

POWER SUPPLY

CABLE

FALC

CABLE

5

6

J-BOX

POWER SUPPLY CABLE

FALC CABLE

7

SCREWS

SIDE PLATE

SIDE

PLATE

GASKET

2

9

“Initial Set-up and Optional Controls”

Summary of Contents for FALC Series

Page 1: ... Motion Sensor is not included or adjustment is not needed the following steps can be skipped MOTION SENSOR DIP SWITCHES FALC LV SHELL COVER SCREWS Microwave Motion Sensor DIP Pin Setting Detection Area Detection area having motion and not enough ambient light will activate the sensor The sensor can be set at 100 75 50 or 10 Hold Time Hold Time refers to the time period the fixture remains at 100 i...

Page 2: ...ALC SF SLIPFITTER 7 8 Move the FALC FIXTURE to the desired tilt angle Mate the teeth of the FALC BRACKET MOUNT and the SLIPFITTER together Tighten the Socket Head Screw with a wrench SLIPFITTER SCREW FALC FIXTURE AC ALC SF Slipfitter Mount AC ALC SF Slipfitter Mount FALC Series LED Area Light Installation Guide Need help Tech help line 800 988 6386 Email cs paclights com Website www paclights com Co...

Page 3: ...nt Follow the Wiring Diagram to properly connect the FALC Fixture For the Round Pole repeat Steps1 6 the same as a Square Pole except the round pole gasket will still be attached to the ARM MOUNT All wiring must be installed by a certified electrician and must be compliant to NEC standards Once all wiring is properly installed fasten the SIDE PLATE back to the Arm Mount Page 3 of 7 SOCKET HEAD SCRE...

Page 4: ... desired tilt angle and fasten the Socket Head Screw Align the teeth from the FALC Bracket Mount to the Trunnion Mount Use the Socket Head Screw to fasten them together You can connect the FALC CABLE to the Power Supply without using a Junction Box only if used with a weather proof connector Page 4 of 7 BOLTS TRUNNION MOUNT SOCKET HEAD SCREW 2 POWER SUPPLY CABLE 3 5 If the Power Supply Cable is ra...

Page 5: ...Rights Reserved STANDARD INSTALLATION STEPS 02 00041 20423 Note Instructions are subject to change at any time without notice Run the FALC CABLE through the Universal Mount and align the teeth from the FALC Bracket Mount with the teeth on the Universal Mount FALC CABLE FALC FIXTURE FALC BRACKET MOUNT UNIVERSAL MOUNT UNIVERSAL MOUNT FALC CABLE FALC BRACKET MOUNT FALC FIXTURE SCREW UNIVERSAL MOUNT F...

Page 6: ...le through the inside of the Arm Mount Align the hole and teeth from the Arm Mount with the FALC Bracket Mount and use the Socket Head Screw to fasten them together at the desired FALC Fixture tilt angle Place the Locking Plate and Gasket inside the Mounting Pole Run the Power Supply Cable through the 0 48 clearance Slot and fasten the FALC Fixture onto the Mounting Pole with the Socket Head Screw...

Page 7: ... be compliant to NEC standards Page 7 of 7 SIDE PLATE SIDE PLATE GASKET SCREWS DRILLING TEMPLATE Run Power Supply Cable through this slot opening into the Arm Mount Ø 0 375 Clearance holes on pole to align with Locking Plate hole locations 5 5 6 25 0 75 0 77 R 24 Remove the 4 Flat Head Machine Screws and the Side Plate before installing onto the FALC Fixture If the Power Supply Cable is coming fro...

Reviews: