FALC Series LED Area Light
Installation Guide
Need help? Tech help line:
(800) 988-6386
Email:
Website:
www.paclights.com
Copyright © 2020 PacLights
All Rights Reserved
Note: Instructions are subject to change at any time without notice
02-00041-20423
AC-ALC-AM can be used on a Round Pole or a Square Pole
DRILLING
TEMPLATE
O 0.69” Run Power
Supply Cable through
this hole opening into
the Arm Mount
O 0.375” Clearance
holes on pole to align
with Locking Plate
hole locations
Drill holes on the square pole
by following the Drilling Template
to mount the FALC to the desired
height.
If the FALC fixture is being installed
to a square pole, remove the round pole
gasket.
Remove the [4] Flat-Head Machine
Screws and the Side Plate before
installing into the FALC Fixture.
Run the FALC Cable through the
inside the Arm Mount. Align the hole
and teeth from the Arm Mount with
the FALC Bracket Mount and use the
Socket Head Screw to fasten them
together at the appropriate Fixture tilt
angle.
Run the Power Supply Cable inside the Mounting
Pole through the 3/8” clearance hole and into the Arm
Mount. Follow the Wiring Diagram to properly connect
the FALC Fixture.
For the Round Pole, repeat Steps1-6 the same as
a Square Pole, except the round pole gasket will still
be attached to the ARM MOUNT.
All wiring must be installed by a certified electrician
and must be compliant to NEC standards. Once all
wiring is properly installed fasten the SIDE PLATE back
to the Arm Mount.
Page 3 of 7
SOCKET HEAD
SCREW
LOCK
WASHER
WASHER
LOCKING
PLATE
ROUND POLE
GASKET
SQUARE
POLE GASKET
AC-ALC-AM
BRACKET
5.5”
6.25”
1.125”
DRILL
HOLES
LOCKING PLATE
ROUND POLE
GASKET
SOCKET HEAD
SCREW
1
2
3
4
5
7
8
9
Prior to installing remove the Locking
Plate from the Arm Mount by removing the
Socket Head Screws. This allows for the
parts to be removed as well. Depending on
whether a round pole or square is used will
determine which parts are needed.
Place the lock plate and gasket
inside the Mounting Pole and fasten
the FALC Fixture onto the pole with
the Socket Head Screws removed in
Step 2.
6
LOCKING
PLATE
SQUARE POLE GASKET
SCREW
SIDE PLATE
SCREWS
SCREW
FALC CABLE
FALC
MOUNT
FALC
ARM
MOUNT
SOCKET HEAD
SCREW
FALC CABLE
POWER SUPPLY
CABLE
SIDE PLATE
SCREWS
ARM MOUNT
MOUNTING
POLE
POLE
ARM MOUNT
MOUNTING
POLE
ROUND POLE
SQUARE POLE
Arm Mount (Round or Square Pole)
AC-ALC-AM
Arm Mount (Round or Square Pole)
AC-ALC-AM
2
9
“Initial Set-up and Optional Controls”