Cabling diagram
WARNING
Make sure position 3 receives the “hot” 115 V ac input. This
position is fused to avoid fire hazard.
Procedure
1. Strip the wires 0.27 inch (7 mm).
2. Attach the wires to the connector as indicated in the
diagram.
Note: Make sure the screws on the PCD connector are tightened
down firmly on the wiring.
CAUTION
Do not pre-tin (solder) the tips of the cables going into the PCD
connector. This can result in a loose connection.
WARNING
The chassis ground must be tied to earth ground. Failure to do
this leaves the potential for severe hazard. Make sure the ground
is connected via the ground stud on the front of the 5630.
3. Plug the mating connector firmly into the 5630.
Rev E
5630 Installation and Hardware Reference Manual
2 - 15
1
2
3
Green - Chassis Ground
White - 115 Vac neutral
NOT fused
Black - 115 Vac HOT
fused