- 13 -
PRE-USE SETUP
The key switch is located on the control panel. When the machine is not in use, remove the key and store it in a
secure location.
TURNING THE UNIT ON/OFF
CIRCUIT BREAKERS
The circuit breakers on the control panel protect the components from high amp-draw. In particular, the scrub
head circuit will draw too many amps when overloaded by improper application setup. Solution flow, floor sur
-
face, and down-pressure should be considered when operating the machine (example: high down-pressure on a
rough floor with no solution flow will overload the circuit). Repeatedly tripping the breaker will cause the need
for replacement.
BATTERY POWER LEVEL & FAULT INDICATOR
BATTERY POWER LEVEL & FAULT INDICATOR
When switched to the ON position, the Battery Power Level Indicator illuminates indicating the battery charge
level. A full charge is indicated when all LEDs are lit. As the power level decreases, the LEDs go out from
right to left.
When the battery charge is depleted, the last red LED will flash and the brush motor will turn off. The vacuum
and traction drive will continue to function allowing final water recovery and transport to the charging station.
NOTE
: Using AGM battery-equipped units after the last yellow LED goes out can reduce the life of the
batteries.
NOTE
: After a fill charge, operate the machine for at least 30 minutes before recharging the batteries again. Do
not leave the batteries discharged overnight.
A flashing B
attery Power Level Indicator
indicates a detected fault. The following is a list of fault codes:
The battery needs to be charged or there is a faulty connection to the battery.
Check the connection to the motor.
The motor has a short circuit.
The controller is being inhibited from driving.
Throttle fault, check the connection.
Controller fault, check connections
Parking brake fault, check the motor connections.
Excessive voltage, check the battery connections.
Summary of Contents for S-24
Page 5: ...PAGE INTENTIONALLY BLANK ...
Page 48: ...RETURN TO TABLE OF CONTENTS 43 FRAME ASSEMBLY ...
Page 52: ...RETURN TO TABLE OF CONTENTS 47 SOLUTION TANK ...
Page 54: ...RETURN TO TABLE OF CONTENTS 49 OPTIONAL CHEMICAL INJECTION SYSTEM ...
Page 64: ...RETURN TO TABLE OF CONTENTS 59 S 24 DISK SCRUB HEAD ...
Page 66: ...RETURN TO TABLE OF CONTENTS 61 S 24 DISK SCRUB HEAD ...
Page 79: ...RETURN TO TABLE OF CONTENTS 74 PAGE INTENTIONALLY BLANK ...
Page 85: ...RETURN TO TABLE OF CONTENTS 80 OPTIONAL CHEMICAL INJECTION SYSTEM ...
Page 86: ...RETURN TO TABLE OF CONTENTS 81 OPTIONAL SCRUBSMART TELEMETRY SYSTEM ...
Page 87: ...RETURN TO TABLE OF CONTENTS 82 PAGE INTENTIONALLY BLANK ...
Page 88: ...RETURN TO TABLE OF CONTENTS 83 DATE MAINTENANCE LOG ...
Page 89: ...RETURN TO TABLE OF CONTENTS 84 DATE MAINTENANCE LOG ...
Page 91: ...RETURN TO TABLE OF CONTENTS 86 PAGE INTENTIONALLY BLANK ...
Page 92: ...www pacificfloorcare com ...