background image

26

100000457   180118-40

TRNT.BODYA

Installer information

Installation of log set

1.  Fill burner tray (Figure 44) with embers so that the baskets are filled and overflowing the burners’ front row 

(Figure 45). Reserve a small amount of embers for final placement. 

2.  Place first log onto the ledge in the firebox taking care that the log is completely set against the rear wall 

of the firebox (Figure 46). 

 Log Set Installation 

3.  Fit the hole in the back of the 2nd log (Figure 47) over the post located on the left hand side of the first log 

indicated by arrow (Figure 47). Once 2nd log is mounted to the first log, position the  lower portion of 2nd 
log so that it is located close to the pilot without covering it, and as close to the front of the firebox without 
interfering with the glass door once installed.  

Tab located on left side of 
burner for #3 log placement 

Figure 44:  Log 3 positioning tab.

Figure 45:  Burner tray with embers.

Figure 46:  Number 1 log set in place.

Figure 47:  2nd log placement.

Summary of Contents for Trenton

Page 1: ...on the rating plate This appliance is not convertible for use with other gases unless a certi ed kit is used This appliance is suitable for installation in a bedroom or bed sitting room Do not store...

Page 2: ...ol 10 Continuous Pilot Intermittent Pilot CPI IPI selection 10 Remote dimmer control Light 10 Low Battery Power Detection 11 Remote Transmitter 11 IFC Module Receiver 11 Warnings and Cautions 11 Maint...

Page 3: ...t terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBST...

Page 4: ...enton gas stove without rst reading and understanding this manual Any installation or operational deviation from the following instructions voids the Paci c Energy Fireplaces Warranty and may prove ha...

Page 5: ...ysical barrier is recommended if there are at risk individuals in the house To restrict access to the gas stove install an adjustable safety gate to keep toddlers young children and other at risk indi...

Page 6: ...rrent Standard for Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A in the USA Installation Requirements The Trenton gas stove installation and venting mus...

Page 7: ...a simple button layout and informative LCD display Figure 1 The remote transmitter is powered by 3 AAA type batteries A mode key is provided to index between the features and a thermostat key is used...

Page 8: ...press the ON OFF Key on the Remote transmitter The Remote transmitter LCD display will only show the room temperature Figure 3 and Figure 4 At the same time the Receiver module will turn off the gas s...

Page 9: ...t temperature is now displayed Figure 10 To adjust the set point press the up or down arrow keys until the desired set point temperature is displayed on the LCD screen of the remote transmitter The Sm...

Page 10: ...tion press the Mode Key Figure 1 to index to the CPI mode icon Figure 15 Pressing the Up Arrow Key will activate the Continuous Pilot Ignition mode CPI Pressing the Down Arrow Key will return to IPI F...

Page 11: ...IFC batteries are low a double beep will be emitted from the IFC module when it receives a command from the remote This is an alert for a low battery condition for the IFC board When the batteries are...

Page 12: ...ve media such as logs and embers Inspect decorative media and burner assemblies for soot buildup If excessive buildup of soot is present have a quali ed service person inspect and adjust unit for prop...

Page 13: ...several tries push the On Off switch for the fireplace to OFF turn off all electric power to the fireplace and call your service technician or gas supplier Note Sufficient time must be allowed for air...

Page 14: ...BODYA Installer information Trenton Gas Stove Dimensions Dimensions Height 30 5 8 inches Width 26 3 4 inches Depth 21 15 16 inches Height to center of Flue Outlet 24 inches 26 3 4 30 5 8 21 15 16 24 F...

Page 15: ...onal oor protector Only requirement is that the oor be stable and strong enough to support the stove Note on corner placement Refer to minimum clearances as shown in Figure 21 Figure 22 Refer to Figur...

Page 16: ...the vent terminal must be maintained as shown in Figure 23 and the Roof Pitch Table Measure clearances to the nearest edge of termination hood NOTE Vent terminal must not be recessed NOTE LOCAL CODES...

Page 17: ...zontal vent run by 2 feet Ensure vent pipe is properly supported Damper Note The damper position is factory set to the closed position Every venting con guration is different and the damper setting ma...

Page 18: ...top of chimney apply a bead of caulking to top of clay liner Slip vent terminal over liner and secure in place with lateral retaining bolts 5 For larger chimneys ashing will need to be constructed acc...

Page 19: ...nal Direct Vent Termination Snorkel Note For proper operation the Snorkel must be oriented so that the vent inlet and outlet are located at the bottom end of the unit as shown in the side view of this...

Page 20: ...ion the Snorkel correctly so that the drain ports are located at the bottom of the unit Exterior facing or siding can butt right up to the sides of the unit and can extend up to 1 from the wall to whi...

Page 21: ...A N A SV4EBR90 4DT EL90S 4DT EL90SB 46DVA E90 46DVA E90B 90 Elbow Swivel N A N A 4D90L 4D90LB SV4E90 SV4EB90 N A N A N A N A NOTE Mixing venting components from different manufacturers is inadvisable...

Page 22: ...certi ed venting for this gas stove See charts on page 21 for a list of approved venting components Figure 32 Co axial venting components Trenton Gas Stove Rear Component Right blower fan Gas supply...

Page 23: ...Figure 34 Please see the gas supply section on page 34 of the manual for requirement of the gas supply Electrical connection An IEC power cord is provided for connection to a standard wall outlet Not...

Page 24: ...re 36 Make sure that the latticed oval panel in the center of the top cover does not slip off as it is not fastened to the larger cover 2 Raise the glass door and safety screen cover Figure 37 and lif...

Page 25: ...that it can be removed Figure 40 3 Remove the glass door together with the retainer frame that it is af xed to Log set pieces The large rear log Figure 41 comes wrapped separately from the smaller log...

Page 26: ...Log Set Installation 3 Fit the hole in the back of the 2nd log Figure 47 over the post located on the left hand side of the rst log indicated by arrow Figure 47 Once 2nd log is mounted to the rst log...

Page 27: ...ts underside which will t onto a protruding tab on the burner Inset of tab 5 Place 4th log as shown in Figure 49 The black charcoal side of the piece must face inwards This log will act as a support f...

Page 28: ...Lower the glass door frame into place Figure 53 making sure that the frame ts into the horizontal slot on the oor of the rebox 2 Align the glass door frame laterally so that its protruding positioning...

Page 29: ...acing toward the log set once it is in place Figure 56 shows the front side of the safety screen This side must be facing the doors once it is in place The safety screen frame is not square and so it...

Page 30: ...top of the screen mesh once the holder is lowered into position Screen mesh Screen mesh Figure 61 shows the screen mesh holder in place with the holder channel keeping the screen mesh in its proper po...

Page 31: ...7 The glass plate tray is located underneath the Trenton Figure 62 and is held in place by two wing nuts one on each side of the tray Changing the glass plate 1 The glass plate is easily installed fro...

Page 32: ...ystem for the first time Operating Procedure The Pro ame 2 Integrated Fireplace Control IFC module is a device that allows automatic ignition and pilot ame supervision and commands the functions of th...

Page 33: ...using liquid propane Venturi adjustment is accessible through an opening in the rear cover See location on Figure 33 on page 22 Some adjustment may be required Damper Adjustment c losed open Figure 68...

Page 34: ...The gas stove input rating is shown in the chart below A drip leg must be installed in the gas supply line going to the gas control valve to minimize the possibility of any loose scale or dirt within...

Page 35: ...gauge to the test ports 4 Turn gas supply back on and verify gas pressure with the gas stove lit and on its highest setting 5 After testing is nished turn off gas supply remove the pressure gauges and...

Page 36: ...talling the new ori ce Loctite 567 Thread Sealant needs to be applied to the threads of the new ori ce to ensure a proper seal when installed To replace the pilot ori ce remove the pilot hood which is...

Page 37: ...0608 Trenton Panel Set Painted 80001867 Trenton Burner 80002056 Trenton Log Set with Embers 80000627 Trenton Blower Right 80000905 Trenton Blower Left 80000904 Trenton Light Housing with Bulb 80000626...

Page 38: ...ion Wiring Diagram Cautio n Labe l all wire s prio r to disc o nne c tio n whe n se rvic ing c o ntro ls Wiring e rro rs c an c ause impro pe r and dang e ro us o pe ratio n Ve rify pro pe r o pe rati...

Page 39: ...39 TRNT BODYA 100000457 180118 40 Installer information Rating Label T he Rating labe l as sho wn is lo c ate d o n the re ar o f the g as sto ve...

Page 40: ...duction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws For technical support please contact your retailer Web site www pacificenerg...