WARNING: Always keep loading door closed when burning. This heater is not designed for open door
burning.
WARNING: No alteration or modification of the combustion air control assembly is permitted. Any
tampering will void warranty and could be very hazardous.
WARNING: Do not use grates or andirons to elevate the fuel. Burn directly on the fire bricks. Replace
broken or missing bricks. Failure to do so may create a hazardous condition.
Restarting After Extended or Overnight Burns
1. Open door and rake hot embers towards the front of the heater. Add a couple of dry, split logs on top of
embers, close door.
2. Adjust air control to high and in just a few minutes, logs should begin burning.
3. After wood has charred, reset air control to desired setting.
4. To achieve maximum firing rate, set control to high "H". Do not use this setting other than for starting or
preheating fresh fuel loads.
DO NOT OVERFIRE THIS HEATER: Attempts to achieve heat output rates that exceed heater design
specifications can result in permanent damage to the heater and chimney.
Average Heat Output Calculation
Seasoned wood has approximately 7500 BTU’s per pound.
Experience will give you the right settings for proper combustion and efficient burning. Remember the correct
air inlet setting is affected by variables such as type of wood, outside temperature, chimney size and weather
conditions. With practice, you will become proficient in operating your heater and will obtain the performance
for which it was designed.
Proper Draft
1. Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your
chimney depends on the length of the chimney, local geography, nearby obstructions and other factors.
2. Too much draft may cause excessive temperatures in the appliance. An uncontrollable burn or a glowing
red stove part or chimney indicates excessive draft.
3. Inadequate draft may cause backpuffing into the room and plugging of the chimney. Smoke leaking into
the room through appliance and chimney connector joints indicates inadequate draft.
Ash Removal
Caution:
Ashes are to be removed only when the heater is cold. Whenever ashes get 3"(76mm) to 4"(102mm)
deep in your firebox, and when fire has burned down and cooled, remove excess ashes. Leave an ash bed
approximately 1" (25 mm) deep on the firebox bottom to help maintain a hot charcoal bed.
SUPER / CLASSIC_030818-32
23
100000813