Procedure
• Install all components of the chimney system to the chimney manufacturer's installation requirements.
• If a roof or ceiling support is used in the installation, you will find the chimney manufacturer's complete
instructions packed with the roof support.
1. Position the floor protection and stove in accordance with the clearances as stated on the label and in
Figure 6.
2. Mark the center position for the hole in the ceiling and roof by using a string and plumb-bob.
3. Check that the intended location will not interfere with floor joists, ceiling joists or rafters before
proceeding further. Adjust if needed.
4. Following the Chimney manufacturer's instructions, cut a hole in the ceiling and roof to suit the chimney
system and frame in the sides. The chimney support is mounted to the framing.
5. Install the Chimney, following the chimney manufacturers instructions and local codes regarding
installation, clearances, vapour barriers, insulation and weater proofing.
Double-Wall Connector
• Use a listed double-wall connector.
• Install all components to the chimney connector manufacturer's installation requirements.
Single-Wall Connector
Smoke pipe must be:
• as short and straight as possible, use six inch diameter, 24 gauge black pipe that is clean and in new
condition.
• secured at every joint and collar with 3 sheet metal screws.
• installed with the crimped or male ends pointing down. The chimney connector shall not pass through
an attic, roof space, closet or similar concealed space, floor, or ceiling. Where passage through a wall, or
partition of combustible material is desired, the installation shall conform to CAN/CSA-B365, Installation
Code for Solid-Fuel-Burning Appliances and Equipment.
6. Install the chimney connector pipe, starting at the stove with the pipe inside the stove collar. This will
carry any liquid creosote or condensation back into the stove. Continue up to the adapter section of the
chimney system and secure to each other. Using a slip section (if allowed) will make it easier to connect
the two systems together.