Warning:
Under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It may
be fired only after the following conditions have been met.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• DO NOT INSTALL IN A SLEEPING ROOM.
• Outside air supply must be used for Mobile Home installations - see Figure 9 on page 15.
This heater must be installed with listed double-wall connector and compatible chimney system,
Clearances to combustible surfaces and materials are shown Figure 6 .
Clearances may be reduced with various heat insulating materials.
Consult local fire codes and authorities for approval.
NOTE:
Install all components to the connector and chimney manufacturer's installation requirements. Consult
your chimney supplier for installation advice.
Procedure:
Follow the instructions for residential installation with the following additional requirements;
• CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/
ROOF MUST BE MAINTAINED.
• Combustion Air is Required. Note: See "Combustion Air" on page 20.
• Attach stove to flooring using two 1/4" x 2" or longer lag screws.
Mobile Home Installation
SUPER / CLASSIC_030818-32
19
100000813