background image

071111-20 

SUPER-SD1 7

FIG. #2

Chimney

Roof fl ashing

Storm collar

*  4" diameter air inlet with rodent 
screen
*  If the crawl space is well ventilated 

Spark arres-
tor rain cap

Radiation shield

Chimney Con-

Chimney Sup-

56" (1422 mm)

Minimum

Minimum 7' (2.1m.)

Ceiling Height

Attachment to fl oor for
mobile homes

Non-combustible
fl oor protector

48"

(1219 mm)

3' (914 mm)

Minimum

Hooded vent or
90 elbow turned 

The chimney may incor-
porate an offset.  To do 
this safely, all sections 
of listed connector, off-
set elbows and chim-
ney section must be 
screwed together by at 
least three sheet metal 
screws per joint.  The 
chimney must be suit-
ably supported by the 
chimney manufacturer's 

Listed Chimney and Chimney Connector

This appliance, when installed in a Mobile Home, must be installed with:

A. One of the following 6" double-wall connector systems:
  1. Security Model DL or DC 

 

5. Metal Fab Model DW

  2. Oliver MacLeod Model PV   

6. Ameri-Tec Model DBSP

  3. Energy Vent 

 

7. Industrial Chimney Model Excel Ultra-Black

  4. Selkirk Metalbestos Model DS 

8. Simpson Dura-Vent Model DVL

B. As well as one of the following compatible chimney systems - All parts 6":

CANADA ONLY: 

Security 

Pro-Jet 

ICC 

Selkirk 

Energy Vent

   

S2100 

H.T.3000 

Excel 2100  Sentinal CF  Commander 5000

Ceiling support 

XSF 

FCS 

SF 

CF-CSP 

CH6LCS

Rafter radiation shield 

 

RRS 

3' Chimney length 

XL3 

SL3 

L3 

CF-36SL 

CH636

2' Chimney length 

XL2 

SL2 

L2 

CF-24 

CH624

Roof fl ashing 

XFA 

RF17 

FA 

CF-FRA 

CH6TCF

Storm collar 

XSC 

SC 

SC 

CF-SC 

CH6SC

Spark arrestor rain cap  XCPE 

RCSA 

CPE 

CF-SA,CT 

CH6RC, SS

   
USA ONLY: 

Security 

Pro-Jet 

Security 

Pro-Jet 

Metalbestos  MetalFab 

Ameritech 

ICC 

Simpson Dura-Vent

   

S2100 

H.T.3000 

ASHT 

HT3103 

SSII 

2100 

TEC HS 

Excel 103HT  Dura/Plus  Dura Tech

Ceiling support 

XSF 

FCS 

SF 

FCS 

T-SFA 

TGCSP 

6PL-CS 

RDS/SQS 

SDP-SB 

SDP-SB

Rafter radiation shield 

 

RRS 

 

RRS 

T-JSMH 

TGRS

3' Chimney length 

XL3 

SL3 

L3 

SL3 

T-36 

TG3 

HS 36 

CL48 

SDP-P 

SDT-P

2' Chimney length 

XL2 

SL2 

L2 

SL2 

T-24 

TG2 

HS 24 

CL24 

SDP-P 

SDT-P

Roof fl ashing 

XFA 

RF17 

FA 

RF 

T-SFA 

TGF 

8RFFU 

VF 

SDP-F 

SDT-F

Storm collar 

XSC 

SC 

SC 

SC 

T-SC 

TGSC 

PL-ASCG 

SC 

SDP-SC 

SDT-SC

Spark arrestor rain cap  XCPE 

RCSA 

CPE 

RCSA 

T-CT 

TGC 

6PL-MPC 

RCS 

SDP-C 

SDT-C

Summary of Contents for SPECTRUM CLASSICDESIGN-D

Page 1: ...llationinstructions Contact local building or fire officials about restrictions and installation inspection requirements in your area TESTED and LISTED to CAN ULC S627 AND UL 1482 Meets the Environmen...

Page 2: ...eosote 4 Formation and Need for Removal 4 Chimney Fires 4 In Case of a Chimney Fire 4 Avoiding a Chimney Fire 4 Assembly 5 Crate Removal 5 Optional Ash Cleanout System Install first 5 Pedestal Kit 5 L...

Page 3: ...maintained in good condition Periodically inspect seals and replace if necessary Follow instructions included in the DR31 WDGKIT kit obtainable from your nearest Pacific Energy dealer 5 DOORGLASS Dono...

Page 4: ...t be lived with Regular inspection and clean ing is the solution The use of dry seasoned wood and ample combustion air will help to minimize the buildup Chimney Fires The result of excessive creosote...

Page 5: ...to bottom pallet 4 Place stove body carefully on its back 5 Using two 3 4 wrench remove 1 x 1 2 bolts and save for later use 6 Remove pallet retaining brackets from stove bottom Optional Ash Cleanout...

Page 6: ...ooring using two 1 4 x 2 or longer lag screws Mobile Home Installation Warning Under no circumstances is this heater to be installed in a makeshift or temporary manner It may be fired only after the f...

Page 7: ...Excel Ultra Black 4 Selkirk Metalbestos Model DS 8 Simpson Dura Vent Model DVL B As well as one of the following compatible chimney systems All parts 6 CANADA ONLY Security Pro Jet ICC Selkirk Energy...

Page 8: ...tallation must meet all local codes Do not connect this unit to a chimney flue serving another appliance Minimum system height is 15 feet 4 6 m measured from base of appliance Double Wall Connector Us...

Page 9: ...o be secured to the structure to prevent dislodging of the air duct Outside air may also be ducted from outside throughthe4 diameterknockoutholeintherearofthe pedestal or leg kit ash box enclosure If...

Page 10: ...for the first 2 3 times it is very important that the room be well ventilated Open all windows and doors Smoke and fumes caused by the curing process may cause discomfort to some individuals Lighting...

Page 11: ...ry replace with gasket 139 5availablefromyourPacificEnergydealer Re install baffle assembly in reverse order The two side pieces of insulation must be tight against the siderails Restarting After Exte...

Page 12: ...ill al low the fan to turn on as the stove heats up to operating temperature It will also shut the blower off after the fire has gone out and the unit cooled to below a useful heat output range Manual...

Page 13: ...latch Excessive Creosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t B...

Page 14: ...ant Nickel CAST 31RSNI 10 Door Handle Assembly WODC 4147C 11 Boost Manifold 4105 12 Firebrick Set BRIC SSERA 13a Brick Rail Left Right SSER RAILSET 14 Replacement Baffle Kit SSER DBAKIT 15 Baffle Pin...

Page 15: ...CAST 31NI Door Casting Radiant Nickel CAST 31RSNI 12 Door Handle Assembly WODC 4147C 13 Boost Manifold 4105 14 Firebrick Set BRIC SSERA 15a Brick Rail Left Right SSER RAILSET 16 Replacement Baffle Kit...

Page 16: ...anding the basic functions of this design Traditionalwoodstoveshadabasiccombustion systemwhichallowedaconsiderableamountof heat energy to escape up the chimney as un burned gases and particulates smok...

Page 17: ...ack 5 Using a 3 4 wrench remove 1 x 1 2 bolts and save for later use 6 Remove pallet retaining brackets from stove bottom Pedestal Kit 1 With the unit on its back and the removable cover facing up ali...

Page 18: ...18 SUPER SD1 071111 20 NOTES...

Page 19: ...L EXTENDED TO THE FRONT SIDES AND BACK AS INDICATED MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION OUTSIDE AIR KIT AND ONE OF THE FOLLOWING LIS...

Page 20: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan B C V9L 6V8 Phone 250 748 1184 Web site http www pacificenergy net Printed in Canada...