13
180516-36
5055.MR30-A
Note: To test the gas pressure, turn off the gas supply to the stove before loosening
test point screws. Verify gas pressures with the stove lit and at the highest setting.
1. Remove switch cover and back panel and locate the valve as seen in (Figure 11).
2. Locate the inlet and outlet test points on the valve which can be seen in (Figure 12).
After locating test ports loosen the screws within the ports using a flat-tip screwdriver.
3. Attach pressure gauge to the test ports.
4. Turn gas supply back on and test pressures.
5. After testing is finished turn off gas supply, remove the pressure gauges and re-tighten
the screws in the test points.
Gas Pressure Testing Procedure
The pilot flame level can
be adjusted by turning the
adjustment screw, using a flat-tip
screwdriver, seen on the valve in
(Figure 12).
Pilot Adjustment
Pilot adjustment screw
Main gas solenoid Pilot solenoid
Outlet pressure
test point
Inlet pressure test point
Pressure
modulator
device
Figure 11: Valve & IFC module location.
Figure 12: valve.
Summary of Contents for MIRAGE 30 SERIES A
Page 33: ...33 180516 36 5055 MR30 A ...
Page 34: ...34 5055 MR30 A 180516 36 ...
Page 35: ...35 180516 36 5055 MR30 A ...