H
N
WALL SWITCH/
SPEED CONTROLLER
Fig. #23
3. Locate the Remote Blower Assembly in the desired wall
or ceiling location, maximum 20’(6.1m) away from the
unit, and secure to the framing.
NOTE: ThE REMOTE hEAT kIT BLOWER/S CAN BE
INSTALLED SO ThAT ANy EDGE OF ThE GRILL IS A
MINIMUM 12"(305mm) FROM ThE CEILING OR WALLS
AND 36"(914mm) FROM ThE FLOOR.
4. Attach the 10”(254) X 3 1/4”(83mm) Transition Boot to
the Remote Blower Assembly and seal with aluminium
duct tape. Run a 6”(150mm) diameter approved Type “B”
venting between the blower and the fireplace. Fasten in
place with screws and seal with aluminium DUCT tape.
5. Locate the make-up air inlet in a desired location in the
chase wall.
6. Attach finishing grills over both inlet and outlet using the
screws provided.
Electrical Wiring
NOTE: ALL ELECTRICAL WIRING MUST BE DONE By
A qUALIFIED ELECTRICIAN.
Consult local codes or, in the absence of local codes,
with the current CSA C22.1 Canadian Electrical Code
and in the USA with the National Electrical Code, ANSI/
NFPA 70 (Latest Edition).
The Optional Remote Heat blower electrical rating: 120V,
60HZ, 80 watts. For your protection against shock hazard,
use only a properly grounded power supply.
This kit includes a junction box, rheostat and cover plate.
The junction box should be mounted in a convenient location
away from the fireplace.
NOTE: ThE REMOTE hEAT kIT BLOWER/S ShOULD BE
WIRED TO A SEPARATE SWITh OR SPEED CONTROL-
LER ThAN ThE CONvECTION BLOWERS ON ThE UNIT.
BLOWER
120 VOLTS
60 Hz
0.7 AMPERES
G (green)
L1 (white)
L2 (black)
BLOWER ASSEMBLY
HEAT DUCT
TRANSITION BOOT
Fig. #24
USE ONLy COPPER CONDCUTORS
TERMINAL
BLOCK
22
5055.7618_210916-32
FP25.BODYA