Firebrick Installation Instructions
ITEM DIMENSIONS
PART NUMBER
A
9” X 4 1/2” X 1 1/4”
(230 mm x 115 mm x 32 mm)
5096.99
B
4 1/2” X 4 1/2” X 1 1/4”
(115 mm x 115 mm x 32 mm)
7847
C
2 1/4” X 9” X 1 1/4”
(57 mm x 230 mm x 32 mm)
7847.3
D
2 1/4” X 4 1/2” X 1 1/4”
(57 mm x 115mm x 32 mm)
7847.1
This package contains 18 full-size firebricks, as well as 5 various cut-size bricks.
With the heater in the upright position, install firebricks as follows:
1. Install the rear firebricks, 4 full-size, two on each side of the baffle tube. Then place 1 brick "C" in the back
left corner as shown below..
2. Install 4 full-size firebricks and one brick "B" as shown on each side of the firebox.
3. Place 6 full-size firebricks and bricks "C" & "D" on the bottom of the firebox in the pattern shown below.
A
B
B
C
D
Figure 31: FP25LE Firebrick layout.
32
FP25 LE 040523-36
100003890