Pach and Company
Chapter 3
Page 15
AeGIS 9000 Series
PROGRAMMING
FUNCTION CODE
LOCAL PROGRAMMING
13
TIME ZONE
•
Time Zone 1-9
is programmable
time zone.
•
Time Zone 0
is 24 hour time zone,
factory programmed.
• Must be in military time format.
• Begin time must be smaller than
end time.
• Time Zones are only valid within
24-hour period.
• Time Zones are used for non-
restricted keypad code, card or
combination of both.
14
HOLIDAY SCHEDULE
01-16 Holiday Schedules can be
programmed. Keep the holiday
schedules up to date every year.
If
holiday schedule (s) is pro-
grammed, Time Zone Schedule(s)
(TMZ) , Auto Unlock
Step 1
Log on to programming mode (see section 3.1). The display shows
Step 2
Enter Function Code 13 then press # and the display shows
Step 3
Enter the Time Zone Number (1-9) then press #, the display shows
Step 4
IF 1 is entered to ADD
the display shows
proceed to step 5
IF 0 is entered to DELETE
the display shows
proceed to step 7
Step 5
Enter the
START TIME HOUR
(military time format) then press # and enter
the
MINUTES
then press # the display shows
Step 6
Enter the DAY OF THE WEEK (1=Mon, 2= Tue, 3= Wed, 4= Thu
5= Fri, 6= Sat, 7= Sun) then press #, the display shows
Step 7
Enter
1 for YES
then press # and return to step 2
or 0 for NO
then press #
and the display shows
Step 8
Select another Function Code to program different field from the table or
press
*
to exit the programming mode.
Step 1
Log on to programming mode (see section 3.1). The display shows
Step 2
Enter Function Code 14 then press # and the display shows
SELECT PROGRAM
ENTER: _ _ PRESS #
Time Zone Number
ENTER: _ PRESS #
ADD=1 DELETE=0
ENTER: _ PRESS #
Start Time: HH: MM
ENTER: _ _ : _ _
Enter another?
YES=1 NO=0: _
On Which Day (s)
ENTER: _ _ _ _ _ _ _
Enter another ?
YES=1 NO=0
SELECT PROGRAM
ENTER: _ _ PRESS #
SELECT PROGRAM
ENTER: _ _ PRESS #
Holiday Number
ENTER: _ _ PRESS #