background image

Follow these safety precautions when operating the PACER INDUSTRIAL MIXERS Dual arm or Single arm 
mixers. 
 
Installation 
1.  Before operating the machine, read this Owner’s manual carefully. 
2.  Ground the machine properly. Be sure to follow proper grounding and electrical procedures. 
3.  Avoid dangerous environments.  Do not use the machine in a damp or wet environment. 
4.  Use the proper power source.  Refer to the machines designation label located on the back of the machine.  

If it is unreadable call our customer service department (1-888-236-1143) before connection the mixer to a 
power source. 

5.  Avoid  extension  cords.  To  minimize  the  risk  of  circuit  overload,  or  improper  electrical  grounding  do  not 

use extension cords. 

 
Operation 
6.  Ensure the can being mixed is securely clamped. 
7.  Keep customers away from mixing area.  Only trained personnel should operate the mixer. 
 
Maintenance 
8.  Do not get the timer, control panel or wiring wet.  Failure to do so could result in electric shock. 
9.  Clean all surfaces of the machine with soap and water.  Do not use any solvent-based cleaners or thinners. 
10. Disconnect machine from power source before cleaning or servicing mixer. 
11. Be sure to maintain the mixer on a regular basis.  Follow the maintenance procedures on page 8. 

Summary of Contents for Dual

Page 1: ...Pacer Dual Pacer Single Arm Mixers Owner s Manual ...

Page 2: ...tion 3 Safety Precautions 4 Installation Instructions 5 Electrical Connections 7 Operating Instructions 8 Air driven models 9 Troubleshooting 10 Wiring Diagrams 11 Parts list 13 Ordering Replacement Parts 20 2 ...

Page 3: ...ompletely and save for future reference Machine Models This manual includes instructions and replacement parts information on all models PACER INDUSTRIAL MIXERS Dual arm and Single arm mixers 115V 60 Hz and 230V 50Hz mixers Mounting bases Counter stand Floor stand Clamp safety covers Left arm safety cover for Single arm mixers Left and right arm safety covers for Dual arm mixers Standard and explo...

Page 4: ...1 888 236 1143 before connection the mixer to a power source 5 Avoid extension cords To minimize the risk of circuit overload or improper electrical grounding do not use extension cords Operation 6 Ensure the can being mixed is securely clamped 7 Keep customers away from mixing area Only trained personnel should operate the mixer Maintenance 8 Do not get the timer control panel or wiring wet Failu...

Page 5: ...e top and bottom of each spring 3 Insert a spring and foot assembly into the recess in the bottom of each corner of the Counter Stand castings 4 Plug the power cord into a grounded receptacle see page 7 Note Explosion proof models are not furnished with a power cord The machine must be hard wired to the power source by a qualified electrician Item Qty Part Number Description 1 2 PIM 00060 Counter ...

Page 6: ...the floor to apply rubber cement Make sure the boards do not touch the suction cups B Clean the floor directly under the suction cups Clean the contacting surface of the suction cups C Apply rubber cement to the contacting surface of the suction cups and the floor directly under the suc tion cups D Allow the rubber cement to dry until it becomes tacky Remove the boards and lower the floor stand to...

Page 7: ...urface that is green with or without yellow stripes is the grounding wire Check with a qualified electrician if you don t completely understand these grounding instruc tions or if you are not sure whether the machine is properly grounded DO NOT MODIFY the plug provided if it won t fit the outlet have a proper outlet installed by a qualified electrician Extension Cords Avoid using extension cords I...

Page 8: ...off The motor will not start again until it has cooled down Mixing Procedure 1 Turn the clamp handle counter clockwise to open the clamp 2 Place the container to be mixed in the clamp and turn the clamp handle clockwise until the container is se cured 3 If mixing only one container on a dual mixer clamp an empty can or a piece of 2 x 4 board in the other clamp 4 After the containers are secured se...

Page 9: ...si to reliably operate the machine and must not exceed 200psi Air driven models require no electrical connection Operation Mixing Procedure Air driven models don t have a timer Control the mixing time by turning the air supply on and off Flammable materials may be mixed in air driven models Maintenance Cleaning In addition to cleaning instructions on page 8 replace the air filter element when dirt...

Page 10: ...lified electrician replace timer Broken worn or loose drive belt Visually inspect drive belt and replace if necessary Worn or damaged clamp plate Replace clamp plate Clamp lead screw and or clamp rods need to be lubricated Apply a thin film of oil to clamp screw and clamp rods Worn or damaged clamp plate Replace clamp plate Faulty timer Have a qualified electrician replace timer Clamps are not pos...

Page 11: ...Pushbutton Timer Dial Timer 11 ...

Page 12: ...Optional Safety Cover Switch Single Arm Mixer Optional Safety Cover Switch Dual Arm Mixer 12 Explosion Proof Model ...

Page 13: ...5 Connector block 12 1 PIM 10003 Counterweight pulley 13 1 PIM 10110 Bearing housing cover 14 1 PIM 10011 Breather valve Item Qty Part Number Description 15 2 PIM 10007 Side seal 16 1 PIM 10008 Front seal 17 1 PIM 10012 Gasket 18 1 PIM 10145 Hex head screw 3 8 24 x 2 00 19 1 PIM 10123 Internal tooth lockwasher 3 8 20 1 PIM 10128 Hex nut 3 8 24 21 4 PIM 10141 Hex head screw 1 4 20 x 75 22 1 PIM 101...

Page 14: ... Rollpin 3 16 x 1 50 Clamp Assemblies Item Qty Part Number Description 10 2 PIM 10157 404 Woodruff key 11 1 PIM 10024 Clamp plate right front 12 1 PIM 10025 Clamp plate right rear 13 2 PIM 10124 Lockwasher internal tooth 7 16 14 2 PIM 10129 Nut hex jam 7 16 20 15 4 PIM 10172 Lockwasher split 3 8 16 4 PIM 10128 Nut hex 3 8 24 17 1 PIM 10173 Right clamp assembly Dual arm mixer only 18 1 PIM 10174 Le...

Page 15: ...fan clip 5 4 PIM 10143 Screw hex head cap 3 8 16 x 1 00 6 4 PIM 10172 Lockwasher split 3 8 7 1 PIM 10033 Drive belt 8 4 PIM 10176 Screw hex head cap 5 16 18 x 7 8 9 4 PIM 10125 Lockwasher split 5 16 10 4 PIM 10120 Flat washer 5 16 USS 11 4 PIM 10136 Nut nylock jam 5 16 18 12 1 PIM 10177 Set screw knurled cup point 5 16 18 x 50 13 1 PIM 10027 Frame weldment Drive Assembly 15 ...

Page 16: ... head self tapping 8 x 25 8 2 PIM 10154 Screw pan head thread cutting 8 18 x 50 9 2 PIM 10181 Screw pan head self tapping 4 24 X 5 16 Item Qty Part Number Description 10 1 PIM 10036 Timer knob 12 1 PIM 10045 Top enclosure 13 1 PIM 10035 Timer 15 minutes 13 1 PIM 10163 Timer 30 minutes 13 1 PIM 10164 Timer 60 minutes 14 1 PIM 10037 Timer plate 15 minutes 14 1 PIM 10165 Timer plate 30 minutes 14 1 P...

Page 17: ...184 Controller 2 2 PIM 10154 Screw pan head thread cutting 8 18 x 50 3 1 PIM 10134 Nut nylock 1 4 20 4 3 PIM 10182 Pushbutton 5 1 PIM 10183 On off switch 6 1 PIM 10168 PB timer plate 7 1 PIM 10118 Flat washer 1 4 SAE 8 1 PIM 10185 Screw flat head socket 1 4 20 x 1 50 17 ...

Page 18: ...22 Lockwasher int ext tooth 1 4 Item Qty Part Number Description 13 6 PIM 10171 Screw pan head self tapping 8 x 5 16 type AB 14 6 PIM 10140 Screw flat head self tapping 8 x 50 type AB 15 1 PIM 10120 Flat washer 5 16 uss 16 1 PIM 10116 Carriage bolt 5 16 18 x 1 75 17 1 PIM 10136 Nut nylock jam 5 16 18 18 4 PIM 10144 Screw hex head cap 5 16 18 x 1 00 19 4 PIM 10125 Lockwasher split 5 16 20 1 PIM 101...

Page 19: ...nylock 5 16 18 6 2 PIM 10147 Screw Hex head 1 4 20 x 1 50 7 2 PIM 10122 Lock washer int ext tooth 1 4 8 1 PIM 10052 Left side brace weld ment PIM 10061 Right side brace weld ment 9 2 PIM 10058 Bumper 10 2 PIM 10152 Screw pan head 8 32 x 75 11 2 PIM 10133 Nut nylock 8 32 12 4 PIM 10141 Screw hex head 1 4 20 x 75 for attaching rear cover 13 4 PIM 10118 Flat washer 1 4 14 4 PIM 10134 Nut nylock 1 4 2...

Page 20: ... of com mon parts for Dual Safety Covers Item Qty Part Number Description 7 1 PIM 10244 Switch actuator safety cover LS 1 PIM 10255 Switch actuator safety cover RS not shown 8 4 PIM 10133 Nut nylock 8 32 9 1 PIM 10245 Standoff switch actuator 10 2 PIM 10152 Screw pan head 8 32 x 75 11 1 PIM 10248 Support bracket switch actuator 12 2 PIM 10254 Screw pan head 8 32 x 1 00 13 2 PIM 10227 Flat washer 8...

Reviews: