25
Operation
FACTORY SETTINGS
The ST 115 system comes equipped with a number of features which may be
adjusted, enabled or disabled as desired by the user. Listed below are the features
and factory settings of each. To change and/or learn about any of these features,
refer to the applicable part of the “Set-Up Mode” portion of this manual.
Table 1. Factory Settings
FEATURE
FACTORY
SETTING
Password
None Entered
Default Temperature Scale (°C/°F)
°F for 115V
Systems
°C for 230V
Systems
"Hi L" (upper) Temperature Limit
482°C (900°F)
"LO" (lower) Temperature Limit
204°C (400°F)
Set Temperature
"OFF"
Tip Offset Constant
"0"
Temperature Setback
Enabled
Setback Time
30 Minutes
Auto Off
Enabled
Time To Auto Off
30 Minutes