background image

©2012 PACE Inc., Southern Pines North Carolina                All Rights Reserved 

    Page 11 of 20 

Digital Display Temperature Controlled Power Supplies 

(ST 50 & ST 115) 

 
Operation 

 

1.  Ensure that the Set-Up procedure has been performed.  Check for the following: 

a)  Handpiece connection to the power source. 
b)  Proper tip installed in handpiece. 
c)  Power cord connection between an appropriate AC supply and the power source. 

2.  Turn the Power Switch On ("I"). 

3.  Press the Scroll Up

 

Key.  The Set Temperature is now displayed, immediately perform 

step 4.  If a Password has been previously programmed into the system, "EP0" will be appear 
on the LED Display at this point. When this message appears, the operator must enter the 
correct Password before adjusting the temperature. 

4.  Adjust the temperature by pressing and holding Scroll Up

 

Key or Scroll Down

 

key.  

Observe the display as the Set Temperature increases first in increments of 5° and then in 
increments of 10°.  When the desired temperature is reached, release the key.   

 
 

NOTE:  

The Set Temperature can only be adjusted within the defined temperature limits.  If 

the upper limit has been reached, the display will read “HiL”, if the Lo limit is reached, the 
display will read “OFF”.  Temperature limits can be adjusted in the Set-Up menu 

 
5.  An offset may be entered if using massive tips.  To enter an offset, simply press the program 

key while the system is in normal operation mode and enter the offset using the keypad.  The 
display will return to normal display mode in 5-7 seconds.  

 

 

Digital Control LED Operation 

 

The colored LED on the power source front panel indicates calibration status.   

 
LED Full On Red
 –

 A fault has occurred. Check handpiece and/or tip heater cartridge. Check 

handpiece connection to front panel.

 

 
LED Full On Green
 –

 Calibration of THC handpiece is complete or SensaTemp handpiece is 

connected 
 

LED Full On Amber –

 Calibration has not been completed (THC irons).  

 

LED Off -

 Unit is in setback or Instant Set Back (ISB cubby) is activated.

 

 
 

LED Display, Normal Operation 

 
The LED Display provides a 3-digit display of temperature information.  The LED Display will show: 
 

1.  A display of "888" on initial power up to ensure that all LEDs on the display are working. 
2.  A display of the software version of the installed microprocessor (e.g., "1-2") for 2 seconds on 

initial power up after the "888" is displayed. 

3.  Actual tip temperature of the connected handpiece during normal operation. 

The tip temperature displayed will flash when the system is in Temperature Setback. 

5.  The displayed temperature will decrease and stabilize at 177°C (350°F) when the system is 

in Temperature Setback. 

6.  "OFF" with stable display when the Set Tip Temperature has been set to Off (below minimum 

set tip temperature).   

Summary of Contents for IntelliHeat ST 30

Page 1: ...B This manual applies to Model Part Number ST 30 7008 0290 01 ST 30E 7008 0290 02 ST 50 7008 0291 01 ST 50E 7008 0291 02 ST 65 7008 0292 01 ST 65E 7008 0292 02 ST 70 7008 0293 01 ST 70E 7008 0293 02...

Page 2: ...led Power Supplies ST 30 ST 65 ST 75 Operation 10 Temperature Dial Lock 10 Analog Control LED Operation 10 Digital Temperature Controlled Power Supplies ST 50 ST 115 Operation 11 Digital Control LED O...

Page 3: ...ce Requirements Domestic Models Export Models ST 30 ST 30E ST 50 ST 50E ST 65 ST 65E ST 70 ST 70E ST 75 ST 75E ST 115 Operates on 97 127 VAC 50 60Hz 80 Watts maximum at 115 VAC 60Hz ST 115E Operates o...

Page 4: ...2012 PACE Inc Southern Pines North Carolina All Rights Reserved Page 4 of 20 Power Supply Features A A B B C D E F C G J I H D E L E K C O P Q R O P Q R S O P Q R ST 30 ST 50 ST 65 FRONT BACK...

Page 5: ...2012 PACE Inc Southern Pines North Carolina All Rights Reserved Page 5 of 20 A B B M E N C L E K C D O P Q R ST 115 ST 75 R P T Q O ST 70 F C G J I H E L K R P T Q O...

Page 6: ...menu functions I Digital control LED Indicates status of power supply J Digital display Displays temperature setting and menu functions K Vacuum inlet Vacuum connection for SX 90 TP 65 TP 100 Handpiec...

Page 7: ...ighly recommended to help protect personnel from solder flux fumes 5 Exercise proper precautions when using chemicals e g solder paste Refer to the Material Safety Data Sheet MSDS supplied with each c...

Page 8: ...pply Connection For ST 65 Only The ST 65 system utilizes an integral air venturi system to provide air pressure and vacuum for any connected PACE handpiece requiring air vacuum Your in house air suppl...

Page 9: ...d end of a male quick fit connector P N 1259 0087 into the free end of the 1 inch 2 5cm length of air hose connected to the FLOW OUT side of the VisiFilter 3 Connect the free end of the 137cm 54 inch...

Page 10: ...Temp Locking Ring closest to the front panel Dial Control LED Operation The colored LED on the power source front panel indicates Power Receptacle output status LED Full On Red A fault has occurred Ch...

Page 11: ...offset may be entered if using massive tips To enter an offset simply press the program key while the system is in normal operation mode and enter the offset using the keypad The display will return t...

Page 12: ...life and save energy the ST 50 and ST 115 systems can be programmed to automatically set back its Tip Temperature to 177 C 350 F after a selected period of handpiece inactivity adjustable 10 90 minut...

Page 13: ...nd the system will return to normal operation If this occurs repeat steps 1 2 and enter the correct Password b The LED Display reads P Choose one of the following options i Press the Program Key to ke...

Page 14: ...the following a Press and release the Program Key to keep the currently stored Auto Off time b Adjust the Auto Off value using the keypad c Press and release the Program Key to proceed to the next st...

Page 15: ...the front of the unit 3 The LED indicator will turn amber while the tip is heating to the desired performance level 4 Once the tip has reached the desired heat level the LED indicator will turn green...

Page 16: ...1 Green 5 260 C 500 F 1207 0446 02 P1 Turquoise 5 5 288 C 550 F 1207 0446 03 P1 Orange 6 316 C 600 F 1207 0446 04 P1 Gold 6 5 343 C 650 F 1207 0446 05 P1 Red 7 371 C 700 F 1207 0446 06 P1 Violet 7 5 3...

Page 17: ...ter setscrew on the Variable Temperature Control knob furthest from front panel using the Temp Locking Key hex key supplied with the system c Position the knob with the pointer aligned to match the te...

Page 18: ...he correct password Open Sensor Error No handpiece is connected to the power receptacle Connect handpiece The handpiece heater assembly sensor is open Refer to the appropriate handpiece manual Shorted...

Page 19: ...p Time Lag 1159 0246 P5 1 Fuse 0 5 Amp Time Lag Export Models 1159 0213 P5 2 Silicone tubing For SX 90 TJ 85 Handpiece 1342 0015 08 3 Quick disconnect male fitting 1259 0087 P1 4 Venturi solenoid kit...

Page 20: ...Y OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Seller will at its option repair or replace any defective products at its facility or other location approved by it at no charge to user or pro...