Specifications
Arm-Evac 250 System Part Numbers
8889-0250 220/240V 50 Hz
8889-0255
110V,
60
Hz
Flow Rate with standard filter*
Single inlet: 288m³/h (170cfm)
Dual Inlet: 170m³/h (100cfm) per
inlet
Flow Rate with Optional Cleanroom Filter*
Single inlet: 255m³/h (150cfm)
Dual inlet: 135m³/h (80cfm) per
inlet
Noise Level*
58dbA at 2 meters
Weight
14Kg (31 lbs)
Size H x W x D
393 x 282 x 365mm
(15.4” x 11.1” x 14.3”)
Housing
18 gauge Steel (static safe)
Number of inlets
Two 75mm (3”)
# of Collection accessories
Two 75mm (3”) or four 45mm
(1.75”) or 50mm (2”)
Maximum duct run
2.5m (8’) per inlet
Standard
Filter
General
Purpose
HEPA
Filter
Filtration
options
Cleanroom
Filter
Adhesive Filter
Extended Life Filter
Economy
Filter
*Airflow and noise levels are nominal figures and will vary based on voltage
Filter Access Cover
Inlet Cover
(one supplied)
Exhaust Vent
(at rear)
Power Inlet
(at rear)
Filter Condition Display
Motor On/Off
CALIBRATE
Motor Speed
On/Off Switch
4