PA SDI-Drives Midi™ / Maxi™
Edition
07.44
Power Automation
3. HARDWARE
3.1 Technical
Data
DIM
SDI – Interface / SDI/RL – Interface
Outputs
V
DC max. 30, AC max 42
Relay “SAFE LOCK”, free Contact (NO), only
for SDI/RL – Interface
A
Min. 10µ, Max. 0.5
Digital Inputs
V
dc
Low 0 … 7 / high 12 … 30
Digital Inputs (LOCK, ENABLE, EN-BRAKE)
only for SDI/RL – Interface
mA
10 at 24V input voltage
V
dc
Low 0 … 7 / high 12 … 30
Digital Inputs (IN1 to IN4)
mA
10 at 24V input voltage
Start delay (IN1 to IN4)
µs
Ca. 1
Switch off delay (IN1 to IN4)
µs
Ca. 2
Jitter (IN1 to IN4)
µs
±
0,5
Analog Inputs
V
dc
+/- 10V
Analog Inputs AIN1 to AIN4,
resolution 12Bit (about 5mV per LSB)
Input
resistance
42 kOhm
Connections
Digital / Analog In-/Outputs (X10)
─
Mini-Combicon FMC 1,5 / 8 – ST – 3,5
(Spring-Cage Type)
J1
SDI input from last participant
─
RJ45
J2
SDI output to next participant
─
RJ45
Back to Contents
SDI Interface Manual
12