P3 International P4490 Kill A Watt Edge Operation Manual Download Page 8

Page 15

Page 16

Specifications : 

Maintenance 

Protect the meter from adverse weather conditions. The meter is not waterproof. 
Do not expose the LCD display to direct sunlight for long periods of time.  
CAUTION : To avoid damage to the meter, do not expose it to sprays, liquids, or 
solvents. 
Clean the exterior of the meter by removing dust with a lint-free cloth. 
Use care to avoid scratching the clear plastic display filter.    
For further cleaning, use a soft cloth or paper towel dampened with water. You can 
use a 75% isopropyl alcohol solution for more efficient cleaning.  
CAUTION : To avoid damage to the surface of the meter, do not use abrasive or 
chemical cleaning agents.  

P3 INTERNATIONAL CORPORATION 

LIMITED WARRANTY 

P3 INTERNATIONAL CORPORATION ("P3") warrants to the original retail purchaser only, that its 
product is free from defects in material or workmanship under the condition of normal use and service 
for a period of six (6) months from the date of purchase.  In the event that a defect, malfunction or 
failure occurs or is discovered during the warranty period, P3 will repair or replace at its option the 
product or component part(s) which shall appear in the reasonable judgment of P3 to be defective or not 
to factory specifications.  A product requiring service is to be returned to P3 along with the sales 
receipt or other proof of purchase acceptable to P3 and a statement describing the defect or malfunction.  
All transportation costs shall be borne by the owner and the risk of loss shall be upon the party 
initiating the transportation.  All items repaired or replaced thereunder shall be subjected to the 
same limited warranty for a period of six (6) months from the day P3 ships the repaired or replaced 
product. The warranty does not apply to any product that has been subject to misuse, tampering, neglect, 
or accident or as a result of unauthorized alterations or repairs to the product. This warranty is void if 
the serial number (if any) has been removed, altered, or defaced.  This warranty is in lieu of all 
warranties expressed or implied, including the implied warranties of merchantability and fitness for 
a particular purpose which are expressly excluded or disclaimed.  P3 shall not be responsible for 
consequential,  incidental or other damages, and P3 expressly excludes and disclaims liability for any 
damages resulting from the use, operation, improper application, malfunction or defeat of any P3 product 
covered by this limited warranty. P3's obligation is strictly and exclusively limited to the replacement 
or repair of any defective product or component  part(s).  Some states do not allow the exclusion or 
limitation of incidental or consequential damages, so the above limitation or exclusion may not apply 
to you.  P3 does not assume or authorize anyone to assume for it any other obligation whatsoever.  
Some states do not allow limitation on how long an implied warranty lasts, so the above limitations may 
not apply to you. It is the owner/user's responsibility to comply with local, state, or federal regulations, 
if any, that may pertain to P3 products or their use.  This warranty gives you specific legal rights, and 
you may also have other rights which vary from state to state. 

Email: 

If you experience difficulty in the operation of your unit, or if your unit requires repair please contact : 

P3 INTERNATIONAL CORPORATION 

TECHNICAL SUPPORT 

Tel: 212-741-7289 

Fax: 212-741-2288 

[email protected]

REV. 0113 

Summary of Contents for P4490 Kill A Watt Edge

Page 1: ...ill shut off power to appliances regardless of standby power after a settable delay The power killer function is ideal for space heaters humidifiers etc The Kill A Watt Edge is also easy to read thanks to a tether feature that allows you to perch your meter nearby the item you are measuring without having to bend over or unplug the device to view data Keep the housing mated together in a single un...

Page 2: ... and the unit standby off power level is larger than appliance instant standby power C The off power delayed time setting value must have elapsed 3 2 Please refer to Standby power Off power delayed time and PIR sensor detecting distance settings for detailed information 4 The shorter the off power delayed time setting the more energy will be saved but the AC power on off cycles will occur more fre...

Page 3: ...O2 W Month Lb SAVE Standby Sensor Enter YES NO Year CO2 W Lb SAVE Standby Sensor Cost mode pressing the center Cost key The Cost mode display can include Total Day Month Year and SAVE Repeated presses will change displays LCD display default will show Total cost and W Watts indicates there will be no display in the Power Kill mode Power ON reset Press Change Screen Key Press Press Press Change Scr...

Page 4: ...by Sensor CO2 Meter Enter YES NO Kwh Total Standby Sensor CO2 Meter Enter YES NO Kwh Total SAVE Standby Sensor CO2 Meter Enter YES NO Total A SAVE Standby Sensor CO2 Meter Enter YES NO W Total SAVE Standby Sensor CO2 Meter Enter YES NO Elap h Total m Time Standby Sensor CO2 Meter Enter YES NO m Total Elap s Time SAVE Standby Sensor Rate setting Reset Clear Press and Hold 3 Second CO2 Flash Screen ...

Page 5: ...onds the unit will turn off power to outlet and also activate the PIR motion detection function When somebody moves into the effective PIR area the unit will turn power on to outletat once The key will illuminate in green PIR sensor The motion detection effective area is a 3 D zone as per the following description when it is not blocked by machines or furniture Please install the PIR and display u...

Page 6: ...ensitivity OFF 1 15 Ft Press Key More range Less range Press Enter Change Screen Year CO2 Rate Kwh CO2 Month Lb Kg Total Day Elap Meter h m s A SAVE m Time V Hr SAVE Year CO2 Rate W Kwh CO2 Month Lb Kg Total Day Elap Meter h m s A SAVE V Hr SAVE Flash Screen Year CO 2 Rate W Kwh CO2 Month Lb Kg Total Day Elap Meter h m s W A SAVE m Time V Hr SAVE Year CO2 Rate Kwh CO2 Month Lb Kg Total Day Elap Me...

Page 7: ...ctivate the PIR motion sensor function and will not turn on power again even when somebody moves into the PIR effective area It is NOT recommended to disable the PIR function Default is 15 feet Alarm mode Over Current When the current load presented by the connected appliance exceeds the max Current 15A the unit will switch to Over Current mode The power will be switched off to the outlet The key ...

Page 8: ...same limited warranty for a period of six 6 months from the day P3 ships the repaired or replaced product The warranty does not apply to any product that has been subject to misuse tampering neglect or accident or as a result of unauthorized alterations or repairs to the product This warranty is void if the serial number if any has been removed altered or defaced This warranty is in lieu of all wa...

Reviews: