Page 13
Page 14
Power kill mode : Off power delayed time and PIR sensor detecting distances
setting :
Off power delayed time : 10 seconds to 12 hours, default is 4 hours.
PIR sensor detecting distances : Off (disable PIR function), 1 foot to 15 feet, default
is 15 feet.
Press
Enter
〈
Flash Screen
〉
Power Kill Mode Setting
Press Key
More time
delay
Select Range
1O sec ~ 12 hour
Press Key
Less time
delay
Press Key
Select Range
Sensitivity
OFF, 1-15 Ft
Press Key
More range
Less range
Press
Enter
〈
Change Screen
〉
Year
CO
2
Rate
W
Kwh
$
CO
2
$
Month
Lb
Kg
Total
Day
Elap
Meter
h
m
s
W
A
SAVE
m
V
SAVE
〈
Flash Screen
〉
Year
CO
2
Rate
W
Kwh
$
CO
2
$
Month
Lb
Kg
Total
Day
Elap
Meter
h
m
s
W
A
SAVE
m
Time
V
Hr
SAVE
Year
CO
2
Rate
W
Kwh
$
CO
2
$
Month
Lb
Kg
Total
Day
Elap
Meter
h
m
s
W
A
SAVE
m
Time
V
Hr
SAVE
Standby
YES
NO
Sensor
Time
Hr
Enter
Standby
YES
NO
Enter
Sensor
Enter
Standby
YES
NO
Sensor
〈
Flash Screen
〉
Year
CO
2
Rate
W
Kwh
$
CO
2
$
Month
Lb
Kg
Total
Day
Elap
Meter
h
m
s
W
A
SAVE
m
Time
V
Hr
SAVE
Standby
YES
NO
Enter
Sensor
Press
Enter
〈
Change Screen
〉
Year
CO
2
Rate
Kwh
$
CO
2
Month
Lb
Kg
Day
Elap
Meter
h
m
s
W
A
SAVE
W
$
Total
m
Time
V
Hr
SAVE
Enter
Standby
YES
NO
Sensor
+
-
1, Default is 4 hour.
2, The shorter the off power delayed time, more energy
will be sa ved, but the AC powe r on / off cyc les will
occur more frequently. The app ropriate setting for off
power delayed time will be to balance appliance use
and save energy.
OFF = Disable PIR function: the unit
will cut power according to the off
power delayed time conditions only .
After off power delayed time setting
value, the unit will cut power . The
LED flashes green every 3 seconds,
and the unit will not activate the PIR
motion sensor function and will not
turn on power again even when
somebody moves into the PIR
effective area. It is NOT
recommended to disable the PIR
function.
Default is
15 feet.
+
-
Alarm mode :
Over Current :
When the current load presented by the connected appliance exceeds
the max. Current (15A), the unit will switch to Over Current mode. The power will be
switched off to the outlet. The key will illuminate in red. LCD will display the OVER
icon and protected current value. Remove the appliance; press the key to erase the
main display, Over icon and protected current value. Then press the key to turn the
power back on.
Retained measurements :
1. When power to the unit is interrupted, cumulative power consumption KWH, Elapsed
Time, Cost, and CO
2
will be retained automatically into EEPROM. All user settings,
Rates, Standby power, Off power delay time, PIR distances are retained in EEPROM
after every user setting. This feature allows settings to be programmed one time only
without loss during power interruptions or when the unit is moved from outlet to outlet.
2. When the AC power is restored or when the unit is plugged into another outlet,
cumulative power consumption KWH, Elapsed Time, Cost, CO
2
, Rate, Standby power,
Off power delay time, and PIR distances will be retrieved automatically from memory.
Over Current after
continuous 5 second
Press
Press
〈
Change Screen
〉
First Over Current
Current Load 15.42 A
〈
Change Screen
〉
〈
Change Screen
〉
CO
2
Rate
Kwh
$
CO
2
Month
Lb
Kg
Day
Elap
Meter
h
m
s
W
A
SAVE
m
Time
V
Hr
SAVE
Year
CO
2
Rate
W
Kwh
$
CO
2
$
Month
Lb
Kg
Total
Day
Elap
Meter
h
m
s
W
SAVE
m
Time
V
Hr
A
SAVE
(Red LED Flash every 0.5 second)
Year
CO
2
Rate
Kwh
$
CO
2
Month
Lb
Kg
Day
Elap
Meter
h
m
s
W
A
SAVE
m
Time
V
Hr
SAVE
-
+
Enter
YES
NO
Year
W
$
Total
Standby
Sensor
-
+
Enter
Standby
YES
NO
Sensor
-
+
Enter
YES
NO
W
$
Total
Standby
Sensor