P3 International P4490 Kill A Watt Edge Operation Manual Download Page 2

Display Panel : 

Installation:  

 

 

$

CO

2

Meter

ON/OFF key with LED indicator

Cost mode icon

And unit ($)

CO

2

mode icon

Save  mode icon

Elapsed time icon

Setting adjustment

Increase button

indicator

Setting adjustment
decrease button
indicator

CO

2

 button

Cost button

Meter button

Unit for CO

2

 mode (Lb & Kg)

Unit for Watts mode (W)

Year, Month and Day icon

Meter unit icon.

Standby Killer icon:

Standby : enabled

Flash: power off

PIR Motion icon:
Steady: No motion
Flash: Motion detected

ON, OFF and PIR detect function : 

1. Pressing the ON/OFF key will turn off power to the outlet at once. The key will illuminate 

    in red. The unit will continue to  measure power (e.g. Voltage, Time) and the function 

    keys and LCD display will continue to operate.

2. Pressing the ON/OFF key again will turn power on to outlet at once. The key will 

    illuminate in green. The unit features a spike-free switch function which activates at 

    zero-crossing and will present clean power to your connected appliance. The unit will 

    measure power and the function keys and LCD display will operate. The unit will be in 

    PIR motion detection mode. 

3. If there is no motion in the PIR effective area, and the appliance is in standby mode, 

    the unit will cut off power according to off power delay time setting. For example, with 

    a 30 minute setting, after 30 minutes, the unit will shut down power, the LED will flash 

    green every 3 seconds, and the unit will be in PIR motion detection mode. When 

    somebody moves into the effective PIR area, the unit will turn power on to outlet at 

    once. The LED will illuminate in green.    

3.1  There are 3 conditions that must be true to cut off power: 

       A, No motion in the PIR effective area,

       B, The appliance is in standby condition, and the unit standby off power level is 

            larger than appliance instant standby power, 

       C, The off power delayed time setting value must have elapsed. 

3.2  Please refer to 

Standby power

,

Off power delayed time 

and 

PIR sensor detecting 

       

distance settings

 for detailed information.         

4. The shorter the off power delayed time setting, the more energy will be saved but the 

    AC power on/off cycles will occur more frequently. The appropriate setting for off power 

    delayed time will be to balance appliance use and save energy. 1 hour for office, 30 

    minutes for home, is a suggested starting point.

5. Summary: 

Remark :  

Flashing segments on the LCD display indicate that this item can be re-set. 

Page 3

Page 4 

1. Before connection to the unit, turn off the appliance and remove the power cord from 
    the outlet. 
2. Plug the appliance’s power cord into the Kill A Watt

®

 Edge unit socket, and then connect 

    the Kill A Watt

®

 Edge into the outlet. 

3. If there are many appliances, please use a power strip, plug all the appliance’s power 
    cords into power strip’s sockets and plug the power strip into Kill A Watt

®

 Edge socket, 

    and then connect the Kill A Watt

®

 Edge into the outlet. 

4. Turn on the appliance within 10 seconds. This time limit is important to ensure correct 
    standby power detection. 
5. Now the Kill A Watt

®

 Edge will measure appliance standby power, the ON/OFF key 

    on the top of the Kill A Watt

®

 Edge will flash in green once per second, which indicates 

    the standby power is being measured. After 30 to 40 seconds, the standby power 
    measuring is finished. The ON/OFF key’s light will be solid green. Now, the unit is 
    working and in PIR motion detection mode.   

4.1  green light = power on, and PIR motion detect function on. 

4.2  red light = power off, and PIR motion detect function off. 

4.3  green light every 3 second = power off, and PIR motion detect function on.

4.4  green light every second = standby power is measuring, don’t touch.           

Summary of Contents for P4490 Kill A Watt Edge

Page 1: ...ill shut off power to appliances regardless of standby power after a settable delay The power killer function is ideal for space heaters humidifiers etc The Kill A Watt Edge is also easy to read thanks to a tether feature that allows you to perch your meter nearby the item you are measuring without having to bend over or unplug the device to view data Keep the housing mated together in a single un...

Page 2: ... and the unit standby off power level is larger than appliance instant standby power C The off power delayed time setting value must have elapsed 3 2 Please refer to Standby power Off power delayed time and PIR sensor detecting distance settings for detailed information 4 The shorter the off power delayed time setting the more energy will be saved but the AC power on off cycles will occur more fre...

Page 3: ...O2 W Month Lb SAVE Standby Sensor Enter YES NO Year CO2 W Lb SAVE Standby Sensor Cost mode pressing the center Cost key The Cost mode display can include Total Day Month Year and SAVE Repeated presses will change displays LCD display default will show Total cost and W Watts indicates there will be no display in the Power Kill mode Power ON reset Press Change Screen Key Press Press Press Change Scr...

Page 4: ...by Sensor CO2 Meter Enter YES NO Kwh Total Standby Sensor CO2 Meter Enter YES NO Kwh Total SAVE Standby Sensor CO2 Meter Enter YES NO Total A SAVE Standby Sensor CO2 Meter Enter YES NO W Total SAVE Standby Sensor CO2 Meter Enter YES NO Elap h Total m Time Standby Sensor CO2 Meter Enter YES NO m Total Elap s Time SAVE Standby Sensor Rate setting Reset Clear Press and Hold 3 Second CO2 Flash Screen ...

Page 5: ...onds the unit will turn off power to outlet and also activate the PIR motion detection function When somebody moves into the effective PIR area the unit will turn power on to outletat once The key will illuminate in green PIR sensor The motion detection effective area is a 3 D zone as per the following description when it is not blocked by machines or furniture Please install the PIR and display u...

Page 6: ...ensitivity OFF 1 15 Ft Press Key More range Less range Press Enter Change Screen Year CO2 Rate Kwh CO2 Month Lb Kg Total Day Elap Meter h m s A SAVE m Time V Hr SAVE Year CO2 Rate W Kwh CO2 Month Lb Kg Total Day Elap Meter h m s A SAVE V Hr SAVE Flash Screen Year CO 2 Rate W Kwh CO2 Month Lb Kg Total Day Elap Meter h m s W A SAVE m Time V Hr SAVE Year CO2 Rate Kwh CO2 Month Lb Kg Total Day Elap Me...

Page 7: ...ctivate the PIR motion sensor function and will not turn on power again even when somebody moves into the PIR effective area It is NOT recommended to disable the PIR function Default is 15 feet Alarm mode Over Current When the current load presented by the connected appliance exceeds the max Current 15A the unit will switch to Over Current mode The power will be switched off to the outlet The key ...

Page 8: ...same limited warranty for a period of six 6 months from the day P3 ships the repaired or replaced product The warranty does not apply to any product that has been subject to misuse tampering neglect or accident or as a result of unauthorized alterations or repairs to the product This warranty is void if the serial number if any has been removed altered or defaced This warranty is in lieu of all wa...