Electrical System Protection
The heater’s electrical system is protected by a circuit breaker that protects the system
components from damage. If the heater fails, check the fuse first, and replace if necessary.
Flame Sensor
The heater uses a photocell to see the flame in the combustion chamber. Should the flame extin-
guish, the sensor will stop electrical current and the heater will shut off.
Fuelling The Heater
It is always a good idea to fire the heater outdoors for the first time. This will allow any oils used in
the manufacturing process to be burned off in a safe environment. This initial burn should last at
least 10 minutes.
CAUTION!
NEVER FILL FUEL TANK INDOORS. ALWAYS FILL FUEL TANK OUTDOORS. BE
SURE THAT THE HEATER IS ON LEVEL GROUND WHEN FUELLING, AND NEVER OVERFILL
FUEL TANK.
!
WARNING!
NEVER REFUEL THIS HEATER WHILE IT IS HOT OR OPERATING, FIRE OR EX-
PLOSION COULD RESULT.
!
Ventilation
Risk of indoor air pollution. Use heater only in well ventilated areas.
Always provide a fresh air opening in the heated space of at least three square feet (2800sq.cm)
for each 29kW/hr of heater output. Provide a larger opening if more heater will require.
- a two-car garage door raised 15.24cm (6 inches)
- a single-car garage door raised 15.24cm (9 inches)
- TWO, a 76cm (30 inches) windows raised 38.1cm (15 inches)
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO
A POWER SOURCE.