background image

3

1. Application.

RK-2001U controller is a device designed for temperature control of solid fuel fired

boilers. The temperature of the boiler is kept on level set by user, by controlling the

speed of the pressure fan. The controller monitors temperature of water in the boiler,

displays it on the display, and controlls circulating pump. To enable more precise

temperature control of heated rooms, the controller is equipped with input for room

thermostat. The controller is equipped with extra programmable multi-functional

output, which allows connecting mixing valve, alarm signal, extra boiler (gas or

oil-fueled), emergency cooling system or other devices turned on simultaneously with

blow-in fan.

2. Connection.

Before turning on the device by master switch, connect controller, pressure fan and

circulating pump power cords to appropriate sockets in the rear of the controller.

Temperature sensor should be placed in measurement hole in the boiler. Picture 2

shows diagram of electrical connection of the device.

WARNING!

Before plugging the device to the power source check if it is proprerly

grounded and if the screws of the connector are properly screwed.

CAUTION!

The maximum total power of devices connected to the controller mustn't

exceed 450W.

CAUTION!

As additional option you can connect the UM-1 module to the controller

that allows controlling the additional boiler or the mixing valve and the hot water

loading pump. It is necessary to protect the power supply of these devices with

suitable cut-outs.

Not used power outs of the controller may remain unconnected.

3. Operation.

After turning the device on, all the elements of the display are lit for a while to check if

they are working properly. The controller, when power appears, returns to its last state

before turning off or power loss.

Front of the device (picture 1) consist of:

1 – Master switch

2 – Display, indicating boiler temperature and parameters

3 – Room thermostat indicator

4 – Boiler thermostat knob

5 – Circulating pump indicator

6 – STOP/choose parameters/erase alarms button

7 – START/choose parameters button

8 – Start programming in service mode/confirm settings button

Summary of Contents for RK-2001U

Page 1: ...OPERATION MANUAL SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER RK 2001U Version 9A15...

Page 2: ......

Page 3: ...ram of electrical connection of the device WARNING Before plugging the device to the power source check if it is proprerly grounded and if the screws of the connector are properly screwed CAUTION The...

Page 4: ...n on the display defines mode which controller currently is in for example 50 STOP mode 50 C WORK mode 50 c keeping fire in WORK mode 4 Setting up the parameters service mode Holding OK button for mor...

Page 5: ...ontrolling extra devices turning on during work of blow in fan 0 4 1 0 Prod Return to factory defaults after pressing OK outP Central heating pump testing press OK launch outP out1 out Fan output test...

Page 6: ...in the boiler which causes start of the circulating pump Circulating pump works independently from the control process and is launched additionally in case of boiler overheat Circulating pump launch...

Page 7: ...ess will be turned off and the display will show the message FUEL You can return to previous mode by pressing STOP button No fuel testing time during fuel firing is finished after the set temperature...

Page 8: ...d pressing OK you can turn the additional boiler the alarm signaling system or the mixing valve servo motor on if the additional module is connected 4 8 Factory defaults You can return to standard set...

Page 9: ...ng STOP button in spite of temperature below 90 C may mean permanent damage of boiler temperature sensor e g if the boiler overheated above 150 C 7 Device removal In case of need to remove the control...

Page 10: ...10 Picture 2 RK 2001U connection scheme Picture 3 UM 1 module connection scheme...

Page 11: ...2 The work mode and pause time of CH pump L 40 Minimum boiler temperature H 85 Maximum boiler temperature h 2 Boiler temperature hysteresis A 99 Boiler overheating temperature Fd60 Fuel shortage testi...

Page 12: ...12...

Page 13: ...13...

Page 14: ...14...

Page 15: ......

Page 16: ...Producer P W KEY 11 200 Bartoszyce ul Bohater w Warszawy 67 tel 89 763 50 50 fax 89 763 50 51 www pwkey pl e mail pwkey onet pl...

Reviews: