9. Notes.
Disp.
Parameter
User
Π100 Fan max work power or max power when Πr 0-10.
n 40 Minimum fan power.
Πh 2 Fan speed decrease coefficient.
Πr 1 Automatic fan speed control and time of fan start.
Πn 5 Fan work time.
Πu 6 Fan pause time.
P 42 Central heating pump launch temperature.
Ph 2 Central heating pump hysteresis.
Pc 2 The work mode and pause time of CH pump.
L 40 Minimum boiler temperature.
H 85 Maximum boiler temperature.
h 2
Boiler temperature hysteresis.
A 99 Boiler overheating temperature.
Fd60 Fuel shortage testing time with burning.
Fb30 Fuel shortage testing time in WORK mode and burning out.
Ar 0
Work mode of extra output:
0– output turning on extra boiler,
1– alarm output,
2– output controlling mixing valve,
3– output controlling emergency cooling system,
4– output controlling extra devices turning on during work of blow-in
fan.