1. Application.

RK-2001E2D controller is a device designed for temperature control of solid fuel fired

boilers. The temperature of the boiler is kept on level set by user, by controlling the

speed of the pressure fan. The controller monitors temperature of water in the boiler,

displays it on the display, and controlls circulating pump. To allow for more precise

control over heated rooms temperature the controller is equipped with room thermostat

and indoor temperature sensor connection. Design of the controller allows attaching

contact room thermostat instead of indoor temperature sensor. The controller is

equipped with extra programmable multi-functional output, which allows connecting

mixing valve, alarm signal, extra boiler (gas or oil-fueled), emergency cooling system

or other devices turned on simultaneously with blow-in fan.

2. Connection.

Before turning on the device by master switch, connect controller, pressure fan and

circulating pump power cords to appropriate sockets in the rear of the controller.

Temperature sensor should be placed in measurement hole in the boiler Picture 2

shows diagram of electrical connection of the device.

WARNING!

Before plugging the device to the power source check if it is proprerly

grounded and if the screws of the connector are properly screwed.

CAUTION!

The maximum total power of devices connected to the controller mustn't

exceed 450W.

CAUTION!

As additional option you can connect the UM-1 module to the controller

that allows controlling the additional boiler or the mixing valve and the hot water

loading pump. It is necessary to protect the power supply of these devices with

suitable cut-outs.

Not used power outs of the controller may remain unconnected.

3. Operation.

After turning the device on, all the elements of the display are lit for a while to check if

they are working properly. The controller, when power appears, returns to its last state

before turning off or power loss.

Front of the device (Pic. 1) consist of:

1 – Master switch

2 – Display, indicating boiler temperature and parameters

3 – Room thermostat indicator

4 – Boiler thermostat knob

5 – Room thermostat knob

6 – STOP/choose parameters/erase alarms button

7 – START/choose parameters button

8 – Start programming in service mode/confirm settings button

9 – Circulating pump indicator

Summary of Contents for RK-2001E2-D

Page 1: ...OPERATION MANUAL SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER RK 2001E2 D Version 9A15...

Page 2: ......

Page 3: ...placed in measurement hole in the boiler Picture 2 shows diagram of electrical connection of the device WARNING Before plugging the device to the power source check if it is proprerly grounded and if...

Page 4: ...ler If the controller isn t in service mode the display shows water temperature of the boiler and the last sign on the display defines mode which controller currently is in for example 50 STOP mode 50...

Page 5: ...olling emergency cooling system 4 output controlling extra devices turning on during work of blow in fan 0 4 1 0 Prod Return to factory defaults outP Central heating pump testing outP out1 out Fan out...

Page 6: ...in the boiler which causes start of the circulating pump Circulating pump works independently from the control process and is launched additionally in case of boiler overheat Circulating pump launch...

Page 7: ...o previous mode by pressing STOP button No fuel testing time during fuel firing is finished after the set temperature is achieved No fuel testing time during work mode Fb30 in WORK mode if temperature...

Page 8: ...set by the producer by choosing Prod option in service mode and pressing OK button After activating this function the device sets each parameter showed in the table to default 4 9 Exiting service mode...

Page 9: ...d if boiler overheats E 3 error means fault and overheating at the same time Appearing of E 1 error on the display without ability to cancel it by pressing STOP button in spite of temperature below 90...

Page 10: ...10 Picture 2 RK 2001E2 connection scheme Picture 3 UM 1 module connection scheme...

Page 11: ...2 The work mode and pause time of CH pump L 65 Minimum boiler temperature H 85 Maximum boiler temperature h 2 Boiler temperature hysteresis A 99 Boiler overheating temperature Fd60 Fuel shortage testi...

Page 12: ...12...

Page 13: ...13...

Page 14: ...14...

Page 15: ......

Page 16: ...Producer P W KEY 11 200 Bartoszyce ul Bohater w Warszawy 67 tel 89 763 50 50 fax 89 763 50 51 www pwkey pl e mail pwkey onet pl...

Reviews: