background image

         

  

 

                  

www.EasyAssemblyRequired.com 

  

                [email protected]  

 

 

Summary of Contents for CS9300 Professional Series

Page 1: ... 1 AND 2 OR 3 AND 4 SEE DIAGRAM BELOW SHOWING UP TO 4 MAIN CABLE RUNS 3 ATTACH ONE SIDE OF THE MAIN CABLE RUN TO THE LEFT TERMINAL 1 OR 3 IF INSTALLING THE 600 WATT TRANSFORMER BY INSERTING THE STRIPPED WIRE APPROX INTO THE BOTTOM OF THE TERMINAL BLOCK ATTACH THE OTHER SIDE OF THE MAIN CABLE RUN TO THE RIGHT TERMINAL 2 OR 4 IF INSTALLING THE 600 WATT TRANSFORMER TIGHTEN BOTTOM TERMINAL SCREWS TO S...

Page 2: ...www EasyAssemblyRequired com info EasyAssemblyRequired com ...

Page 3: ...2 main cable must be split in the middle to create a left and right side Strip the outer insulation from each wire approximately of an inch to expose the copper stranded wires Left Wire Right Wire Strip Length Approx ...

Page 4: ...htly for each side For more than one home run cable twist the strands of copper wire together combining each side together tightly as shown in 5 to make a completed wire harness Make sure the left and right sides of each cable are separated Left Wires Right Wires Two 2 Main Cables ...

Page 5: ...the wire harness in the bottom side of Terminal 2 and tighten the bottom screw to secure the wires Do not exceed a total of 250 Watts combined for all fixtures attached to the cables in Terminal 1 and Terminal 2 to avoid overloading the circuit You can typically run 3 main cables in each terminal if you need to add another home run Left Wires Right Wires ...

Page 6: ...egarding total maximum wattage and number of main cable runs as in the previous page for Terminals 1 and 2 Be sure to balance the wattage load between both sides circuits of the 600 watt transformer Remember Terminals 1 and 2 make up the first 300 watt circuit and Terminals 3 and 4 make up the second 300 watt circuit Left Wires Right Wires ...

Page 7: ... TCC not the Main Supply Cable Do not exceed 25 feet in length from each side of the T Connector 50 ft total NOTE The TCC is a continuous cable from end to end DO NOT CUT TCC in half To eliminate the possibility of creating a short circuit offset the ends of the TCC by clipping one side as shown below Main Supply Cable T Connector Cable TCC ...

Page 8: ...wer is OFF ON Manual over ride power is ON 2 4 6 or 8 HRS Lights on at DUSK and OFF after 2 4 6 or 8 hours DUSK DAWN Lights on at DUSK and OFF at DAWN When used outdoors plug timer only into a GFCI protected receptacle Receptacle should be mounted in an approved weatherproof while in use type outlet box NOTE Timer must be mounted where accessible to sunlight for dusk down features CS9300 Professio...

Reviews: