Spark plug
Clean and adjust after every 600 operating hours or as required:
-
Remove the top shield.
-
Remove the fan.
-
Remove the ignition lead from the spark plug.
-
Remove the spark plug from the burner head.
-
Clean and adjust the electrodes (3.5 mm).
-
Replace the spark plug on the burner head.
-
Replace the lead on the spark plug.
-
Replace the fan and the top shield.
Spark plug lead
Gap
Burner head
Spark plug