Storage
In case of longer storage periods (more than 30 days), the generator should be
emptied of fuel:
•
Empty the tank.
•
Start the engine and let it operate until all of the fuel is used up.
•
While the engine is still warm, drain the oil from the crank housing. Re-fill with the
recommended oil type.
•
Remove the spark plug and fill the cylinder with approx. 15 ml of engine oil. Cover the
hole with a cloth and pull the recoil start a couple of times to lubricate the cylinder
ring and top part.
•
Put back the spark plug and tighten. Do not fit the cable.
•
Clean the generator on the outside. Ensure the cooling rack and openings to the
generator are open and not blocked. Use a damp cloth. NEVER use a jet of water.
•
Store the generator in a clean and dry place. Ideally indoors and covered, so that the
generator is protected from dust and dirt. Ensure that the cover is suitable for the
purpose and does not retain humidity.
•
Do not store petrol from one season to the next. Always use only pure and fresh
petrol. Rust and dirt can cause problems with the carburettor and the fuel system.
Drain screw