SPECIFICATION / REPLACEMENT PARTS
Unit
EX6
Voltage
230V ~ 50Hz
Dimensions(mm)
270 x 140 x 260
Coverage
20 Sq. Meters
Weight
3.5 Kg
Light Output
6W
Tubes
1 x I617
Starter
1 x I154
Tray
T001
Unit
EX16
Voltage
230V ~ 50Hz
Dimensions(mm)
360 x 140 x 260
Coverage
40 Sq. Meters
Weight
4 Kg
Light Output
16W
Tubes
2 x I621
Starter
2 x I154
Tray (W / S/S)
T003 / T004
Unit
EX30
Voltage
230V ~ 50Hz
Dimensions(mm)
510 x 140 x 260
Coverage
80 Sq. Meters
Weight
6.5 Kg
Light Output
30W
Tubes
2 x I616
Starter
2 x I154
Tray (W / S/S)
T005 / T006
Unit
EX40
Voltage
230V ~ 50Hz
Dimensions(mm)
660 x 140 x 260
Coverage
120 Sq. Meters
Weight
8.5 Kg
Light Output
40W
Tubes
2 x I618
Starter
2 x I154
Tray (W / S/S)
T007 / T008
C
2009
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
P+L Systems Ltd
Ten St James Business Park
Grimbald Crag Court
Knaresborough
HG5 8QB UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
E [email protected]
R2 02/09
TUBE REPLACEMENT
BEFORE REPLACING THE TUBES, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
To ensure the efficiency of
Exocutor
™
in catching flying insects, the UV tubes should
be replaced annually. After twelve months the phosphor coating that emits the
correct wavelength of UV light has burnt away and the UV output is diminished
substantially.
To replace the UV tubes…
1. Rotate the tube through 90°, freeing it from the tube holders.
2. Pull the tube away from the chassis.
3. Dispose of the used UV tube in conjunction with local WEEE regulations.
STARTER REPLACEMENT
BEFORE REPLACING THE STARTERS, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
The starters provide an extra spark to initially light the UV tube. Starters wear out and
should be replaced at the same intervals as the UV tubes.
To replace the starters…
1. Rotate the starter anti-clockwise.
2. Pull the starter free from the unit.
TRAY REMOVAL
The tray is connected to the power supply of the unit via a hidden switch. By
removing the tray, the connection is broken and power is cut to the unit. This
ensures safe access to the unit for servicing and cleaning.
When replacing the tray ensure it is pushed fully into position and that the
connection is made to power the unit.
Tube Replacement
Starter Replacement
WEEE Compliance No. 01576542