……………………………………………… USER AND MAINTENANCE HANDBOOK L150A
P.Energy
P.Energy
P.Energy
P.Energy
24
-
30
5.
MACHINE MAINTENANCE
5.1.
ORDINARY MAINTENANCE
The table below shows the action needed at planning time in order to maintain the efficiency of laminator, note: The hour refers to PARAMETER hours on screen
parameters of the touch screen.
WHERE NOT EXPLICITLY INDICATED THE ORDINARY MAINTENANCE MUST BE DONE WITH LAMINATORE TURN OFF, WITHOUT VOLTAGE, PNEUMATIC CIRCUIT
OPEN, HYDRAULIC CIRCUIT OPEN AND EMPTY, COLD LAMINATOR PLATE.
h
Operation/
HOW TO COMPLETE THE OPERATION
8
After each shift
clean the
laminator plate
with carefulness.
Check membrane;
Check the safety
light guard.
See chapter 3.1
24
Check oil level of
vacuum pump
See vacuum pump handbook attachment
250
Cleaning the slide
shoe and slide
and greasing
with cleaning rag remove any dust and greasing
Check cleaning of
nut and greasing
with cleaning rag remove any dust and greasing
500
Change oil
vacuum pump
See vacuum pump handbook attachment
1000
Cleaning of
radiator, motor
fun protection
and vacuum
pump.
See vacuum pump handbook attachment
Change oil filter of
vacuum pump
See vacuum pump handbook attachment
CHECK THE SEAL
OF REDUCTION
GEAR SEAL
Open the lid to the end position and leave in this position, removing power supply for at least 8 hours, check after that the lid
position has not moved from initial position.
Check
opening/closing
lid, vacuum
circuit, heating
plate, cooling
system
functionality,
drain of hydraulic
circuit
See chapter 3.1
2000
Replacement of
vacuum pump
strainer
See vacuum pump handbook attachment