2.
SAFETY
2.1.
INTRODUCTION
It is forbidden to use the machine for reasons other than that describe above, and/or by person who are not suitably trained.
2.2.
GENERAL SAFETY RULES:
1.
Always keep clean and tidy the work area
2.
Do not leave tools or spanners on the machine, or near to it. After any maintenance work or the replacement of accessories, check carefully, before
switching on the machine.
3.
Always be sure that you are in a safe position with respect to the machine in a secure, well-balanced position.
4.
Never leave the machine unsupervised
5.
All the operations of normal or special maintenance carried out on the machine, as well as cleaning ad running the machine must only be undertaken
by trained personnel
6.
Any normal or special maintenance work must only take place with the machine stopped and electrical supply cut off, the pneumatic and hydraulic
plant must only be carried when the pressure has been released from the equipment
7.
Before each work shift, ensure that the safety system operate correctly
8.
The working place have to be protected from atmospheric conditions
2.3.
MACHINE CONNECTIONS:
It is responsibility of the client to set up the electrical and pneumatic supply system of a suitable size to withstand small power surges of the laminator, see data
sheet present on the
SUPPORTING DOCUMENTS
The electrical and pneumatic supply system to be connected to the plant must only be carried out by qualified personnel, and carried out according to general
regulations for electrical plant installation
2.4.
GROUNDING SYSTEM
It is responsibility of the client must be connected to an efficient grounding system
2.5.
MACHINE SAFETY SYSTEM
•
MECHANICAL
a)
Protective panel in painted sheet metal, protecting the electrical and pneumatic plant
b)
Protective panel in painted sheet metal, protecting the danger area
c)
The cover movement is controlled by a sensor maximum openness and a sensor minimal.
d)
The access door to the electrical panel is fitted with a main switch for the main machine electrical power supply. This is of the type that can be
padlocked and is fitted with mechanical lock, which does not allow the electrical cabinet to be opened unless the switch is at the “0” position.
e)
The speed of descent and ascent of the cover is sufficiently slow so that the operator has the time to evaluate the potential risk.
f)
The laminator is designed to be used by a single operator to operate the movement of the cover must use the special command with two hands.
•
ELECTRICAL
a)
All perimeter of laminator is protected by an infrared barrier that blocking the cover movement in case of introductions.
b)
The electrical circuit is protected by thermal-magnetic circuit breaker and fuse
•
TOWER SIGNAL LAMP:
- Red lamp: danger
-Green lamp: fixed lamp =automatic cycle; Blinking lamp = pre-start conditions reached.
-Blue lamp: cooling circuit activated
•
SIREN, it signals with an acoustic signal, the alarm presence ( fixed sound), and the cover movement (
Intermittent sound)
2.6.
IDENTIFYING THE ZONES OF RESIDUAL RISK NEAR THE MACHINE
the area along the entire perimeter of the laminator to a width of 1 meter can be a source of hazard for the operator if the rules of behavior are not respected
and
if the operator fails adequately monitor the working area