Every situation is highlighted as follows:
-
DL11 red LED lighting up to indicate charge faults
-
DL11 and DL20 red LED lighting up to indicate discharge faults
-
DL11 and DL20 red led lighting up to indicate system faults
-
prompt message on the display containing a fault code and description
If different faults are active at the same time, they are displayed in subsequent windows.
SYSTEM FAULT-Pnn
cc-fault descrip.1
cc-fault descrip.1
cc-fault descrip.1
Where:
nn
= Active fault warning window (1 to 15)
Window no. 1 always shows the most recent faults.
cc
= Active fault code
description
= Active fault description
The keys on the control panel feature following functions:
Esc
:
exits from the faults display without resetting
à
:
moves the failure list selection to the top (i.e. shows the most recent faults)
õ
:
moves the failure list to the bottom (i.e. shows the least recent ones)
C
:
resets ongoing failure indications, which are not active any longer
Failure indications are usually saved.
To reset them, the operator must press
C.
The system can reset some specific faults automatically.
The most relevant faults interrupt the charging and discharging processes and need to be checked by the
operator.
Once the problem generating the fault has been solved and the fault warning reset, the display returns
automatically to the normal operating status.