DIMENSIONAL DRAWING 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

INSTRUCTIONS 

 

SELECTION  
This  product  is  to  be  utilized  with  clean  fresh  water,  even  slightly  additivated  with  normal  detergents.  For  use  involving  different  or 
corrosive liquids, contact the PA Technical department. Appropriate filtration should be installed when using unclean liquids. Choose 
the valve in line with the data of nominal running (system rated pressure, max flow and max temperature). In any case, the pressure of 
the machine should not exceed the permissible pressure rate imprimed on the valve. 
 
INSTALLATION  
This  accessory,  on  a  system  that  produces  hot  water,  must  be  fitted  in  front  of  the  heat  generator.  This  product  is  bound  to  be 
incorporated on a finished machine. On a system that generates hot water, anticipate the fitting of accessories that limit the accidental 
increase of fluid temperature.  
 

Always install a safety valve that protects the pressurized outlet channel. 

Choose  a  correct  nozzle  size,  which  allows  a  regular  discharge  on  bypass,  at  least  5%  of  the  total  flow  of  the  system  in  order  to 
achieve a constant pressure value and avoid troublesome pressure spikes at closure. If the nozzle wears out, the pressure drops.   
On installation of a new nozzle, re-adjust the system to the original pressure setting 
OPERATIONS 
The  valve  regulates  the  the max  pressure  of the  system through  a  piston,  which  acts  on  a  ball that,  normally  positioned,  closes  the 
bypass opening. A check valve cuts out the delivery section, the pressure of which controls the drive of the piston.  
Each regulation should be made when the system is operational and the nozzle open. 

 

ATTENTION:  The  nut  (pos.15)   must  never  be  removed mainly  because,  it is  a mechanical  safety  feature  that  limits  the 
max pressure and avoids serious damage to persons and machine. 

 
DISCHARGE SYSTEM AND WATER ADDUCTION 
The bypass line should be returned into a tank with deflectors. With elevated pressure intake, it is necessary to install a pressure 
reducer in order to have an even flow supply and to protect the circuit intake. 
When  the  system  is  opened  and  closed  frequently,  it  is  recommended  to  install  a  thermal  protector  valve  (VT3  or  VT6)  in  order  to 
eliminate excessive temperature build. 