Waterzone Series

 

Ozone Injection System

 

Model: 

Water zone 20

 

Installation & Operations Manual

 

451 Black Forest Road, Hull, Iowa, 51239 | 712.439.6880 | [email protected]

 

www.ozonesolutions.com

 

Summary of Contents for Waterzone 20

Page 1: ...Waterzone Series Ozone Injection System Model Waterzone 20 Installation Operations Manual 451 Black Forest Road Hull Iowa 51239 712 439 6880 info ozonesolutions com www ozonesolutions com...

Page 2: ...2...

Page 3: ...n Guidelines 10 Operator Startup 11 SECTION 4 HMI Control Display Overview 12 HMI Control Display Root Screen 13 SECTION 5 Warranty 14 Contact Information 14 SECTION 6 Troubleshooting 15 Appendix A CA...

Page 4: ...zone Generator and Ozone Injection System automatically Each of these functions will be described in this manual Please read and famil iarize yourself with this and other related Opera tion Manuals be...

Page 5: ...t least 20 PSI lower than the inlet pressure This pres sure differential creates a vacuum that will pull the ozone into the venturi This forceful action along with the added mixing vanes in the ventur...

Page 6: ...6 SECTION 2 Component Diagram 1 2 3 4 5 6 7 7 8 9 10 11 12 13 14 15 16 17...

Page 7: ...ncrease or decrease along with this pressure but a constant differential will be maintained as long as the Injector Pump is operating properly 7 Water Trap These units prevent water from flowing with...

Page 8: ...d be protected from rain and splash ing water Filtered cooling inlets provide a level of pro tection against dust however for maximum longevity the system should be located in a clean dry area If the...

Page 9: ...away from human contact or to a suitable ozone destruct unit as it will be off gassing small amounts of high concentration ozone Ozone compatible tubing and fittings should be used for this purpose S...

Page 10: ...for human safety Injector Pump The Injector Pump is a dedicated pump to mix the ozone with the water This pump will create the necessary pressure differential across the Venturi Injector to create the...

Page 11: ...or this flow This flow is adjusted manually using the flow control valve near the flowmeter and may be affected by varying water pressures Normally if adequate water pressure is applied to the contact...

Page 12: ...compo nents operate automatically while the HMI panel displays the current status of each part of the system Various set points to adjust running parameters and alarm parameters can be adjusted by th...

Page 13: ...13 HMI Control Display Continued...

Page 14: ...utions for any transportation charges labor or cost for or during the replacement of any parts The replaced part s or product will then continue the original warranty duration The replaced parts will...

Page 15: ...flow is too low Increase oxygen flow Water flow is too high Decrease water flow Ozone Output is low Increase ozone generator output ORP high Check ORP Set points Low outlet pressure Increase inlet flo...

Page 16: ...16 Section 6 Appendix A CAD Drawing...

Page 17: ...cement filter Compressor Inlet Air Filter Replace inlet air filter 3 months as needed CP Filter 4 Replacement Element Dissolved Ozone Monitor Replace cap and electrolyte 6 months as needed AS 500 Flat...

Page 18: ...18 Appendix C OSHA...

Page 19: ...19...

Page 20: ...2 439 6880 info ozonesolutions com www ozonesolutions com 2016 Ozone Solutions All Rights reserved Ozone Solutions is a registered trademark This publication may not be reproduced in part or whole wit...