O3 GENERATOR COOLING WATER IN: is the 1/4 
inch brass female NPT fitting on the side of the control-
ler near the cooling water flow meter. This must be 
connected to a consistent water supply of cool fresh 
water.

 

O3 GENERATOR COOLING WATER OUT: is the 
1/4 inch  brass female NPT fitting on the side of the 
controller near the cooling water flow meter. This is the 
drain from the ozone generator cooling loop. This water 
should be plumbed safely to a drain.

 

Water Sample Port

 

Ozone residual in the water must be checked periodi-
cally to ensure proper operation of the Ozone Injection 
System. This is also used to calibrate the dissolved 
ozone sensor (if applicable). After the output of the 
Ozone Injection System, a small tee with a ball valve 
should be placed in the water line. This will allow for 
samples of water to be pulled to verify the dissolved 
ozone level in the water.

 

Dissolved Ozone Monitor

 

The dissolved ozone probe is shipped installed. This 
probe is shipped with a protective cap on the end to 
keep it protected from damage, and keep it moist. This 
probe will be damaged if it becomes dry.

 

Read and understand the instructions provided for the 
sensor before installing it into the line. Install it only 
after all other plumbing for the Waterzone is complet-
ed, and the system is ready to be filled with water.

 

ORP Sensor

 

The ORP probe is shipped installed. This probe is 
shipped with a protective cap on the end to keep it pro-
tected from damage, and keep it moist. This probe will 
be damaged if it becomes dry.

 

Read and understand the instructions provided for the 
sensor before installing it into the line. Install it only 
after all other plumbing for the Waterzone is complet-
ed, and the system is ready to be filled with water.

 

Air Vent

 

The air vent is located on the top of the Contact Tank. 
The 1/2 inch port exiting the air vent will need to be 
plumbed outdoors away from human contact or to a 
suitable ozone destruct unit, as it will be off

-

gassing 

small amounts of high

-

concentration ozone. Ozone

-

compatible tubing and fittings should be used for this 
purpose.

 

 

Some Waterzone systems are configured with an 
Ozone Destruct Unit installed on the skid. If pre-
sent, the gas exiting this ozone destruct unit 
should still be plumbed to a safe location in the 
event the destruct unit fails for any reason. It is 
important that this gas is removed from human 
contact and vented to a safe location.

 

Water Trap Drain

 

The Water Trap is located on the Ozone Injection 
Skid. This water trap will drain any water that 
may be pushed from the Venturi Injector toward 
the Ozone Generator; this is a protection device 
for the Ozone Generator. There may also be a wa-
ter trap installed to drain any water from the off

-

gas vent outlet prior to the ozone destruct unit.

 

These water traps may collect a small amount of 
water that will need to be plumbed away to a 
drain. Any drain tubing must be run DOWNHILL 
in order to freely drain. Use tubing with an ID of 
no less than 3/8 inch, with a maximum if 5 feet.

 

Electrical Power Connections

 

The system requires a 120 Volt, 3

-

wire, 20 Amp, 

50/60 Hz single phase circuit. The unit is installed 
with a NEMA cord end for easy power up.

 

Optional Electrical Connections

 

CAUTION: Voltage may be present at connection 
terminals! Disconnect all power before servicing.

 

Terminals are provided for connection of external 
contacts to control and monitor the system. The 
terminals are located inside the System Controller. 
Drill holes in the System Controller as necessary 
for connection of external control wiring.

 

These connections may be used optionally as de-
sired. Some terminals are jumpered from the fac-
tory to allow the system to operate without exter-
nal connections. On terminals which are jump-
ered, the jumper must be removed upon connec-
tion of remote contacts.

 

If control wires are used in the terminals currently, 
these can be run in series with any remote control 
device of your choice to power the system        
remotely.

 

Summary of Contents for Waterzone 20

Page 1: ...Waterzone Series Ozone Injection System Model Waterzone 20 Installation Operations Manual 451 Black Forest Road Hull Iowa 51239 712 439 6880 info ozonesolutions com www ozonesolutions com...

Page 2: ...2...

Page 3: ...n Guidelines 10 Operator Startup 11 SECTION 4 HMI Control Display Overview 12 HMI Control Display Root Screen 13 SECTION 5 Warranty 14 Contact Information 14 SECTION 6 Troubleshooting 15 Appendix A CA...

Page 4: ...zone Generator and Ozone Injection System automatically Each of these functions will be described in this manual Please read and famil iarize yourself with this and other related Opera tion Manuals be...

Page 5: ...t least 20 PSI lower than the inlet pressure This pres sure differential creates a vacuum that will pull the ozone into the venturi This forceful action along with the added mixing vanes in the ventur...

Page 6: ...6 SECTION 2 Component Diagram 1 2 3 4 5 6 7 7 8 9 10 11 12 13 14 15 16 17...

Page 7: ...ncrease or decrease along with this pressure but a constant differential will be maintained as long as the Injector Pump is operating properly 7 Water Trap These units prevent water from flowing with...

Page 8: ...d be protected from rain and splash ing water Filtered cooling inlets provide a level of pro tection against dust however for maximum longevity the system should be located in a clean dry area If the...

Page 9: ...away from human contact or to a suitable ozone destruct unit as it will be off gassing small amounts of high concentration ozone Ozone compatible tubing and fittings should be used for this purpose S...

Page 10: ...for human safety Injector Pump The Injector Pump is a dedicated pump to mix the ozone with the water This pump will create the necessary pressure differential across the Venturi Injector to create the...

Page 11: ...or this flow This flow is adjusted manually using the flow control valve near the flowmeter and may be affected by varying water pressures Normally if adequate water pressure is applied to the contact...

Page 12: ...compo nents operate automatically while the HMI panel displays the current status of each part of the system Various set points to adjust running parameters and alarm parameters can be adjusted by th...

Page 13: ...13 HMI Control Display Continued...

Page 14: ...utions for any transportation charges labor or cost for or during the replacement of any parts The replaced part s or product will then continue the original warranty duration The replaced parts will...

Page 15: ...flow is too low Increase oxygen flow Water flow is too high Decrease water flow Ozone Output is low Increase ozone generator output ORP high Check ORP Set points Low outlet pressure Increase inlet flo...

Page 16: ...16 Section 6 Appendix A CAD Drawing...

Page 17: ...cement filter Compressor Inlet Air Filter Replace inlet air filter 3 months as needed CP Filter 4 Replacement Element Dissolved Ozone Monitor Replace cap and electrolyte 6 months as needed AS 500 Flat...

Page 18: ...18 Appendix C OSHA...