background image

– 

Wear ear protectors.

 Exposure to noise can cause hearing loss.

– 

Use auxiliary handle(s), if supplied with the tool.

 Loss of control can cause personal injury.

– 

Hold power tool by insulated gripping surfaces, when performing an operation where the 

cutting accessory may contact hidden wiring or its own cord. 

Cutting accessory contacting a 

“live” wire may make exposed metal parts of the power tool “live” and could give the operator an 

electric shock.

WARNING! 

This appliance is not intended for use by persons

 (including 

children) with reduced physical, sensory or mental capabilities, or lack of 

experience and knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by a person responsible for their safety.

Recommendations for the use of a residual current device

 with a rated residual 

current of 30mA or less.

Using an Extension Lead

•   Always use an approved extension lead suitable for the power input of this tool. 

Before use, inspect the extension lead for signs of damage, wear and ageing. 

Replace the extension lead if damaged or defective.

•   When using an extension lead on a reel, always unwind the lead completely. 

Use of an extension lead not suitable for the power input of the tool or which is 

damaged or defective may result in a risk of fire and electric shock.

•   It is recommended that the extension lead is a maximum of 25m in length. Do Not 

use multiple extension leads.

•   Before drilling into walls, ceilings etc, ensure there are no concealed power cables 

or pipes in the cavity.

•   Always use the side handle, this gives you greater control if the accessory should 

become jammed.

•   Keep the cord clear of the accessory being used, do not wrap the cord around 

your arm or wrist.

•   Hold the tool by the insulated gripping surfaces when performing an operation 

where the accessory may contact hidden wiring or its own cord.

•   Use thick cushioned gloves and limit the exposure time by taking frequent breaks.
•   Vibration caused by the hammer action may be harmful to your hands and arms.
•   When removing an accessory from the tool avoid contact with skin and use proper 

protective gloves when grasping the bit or accessory. Accessories may be hot 

after prolonged use.

  WARNING!

 Some dust created by power sanding, sawing, grinding, drilling 

and other construction activities contain chemicals known to cause cancer, birth 

defects or other reproductive harm.
Some examples of these chemicals are:
•   Lead from lead-based paints;
•   Crystalline silica from bricks, cement and other masonry products, and;
•   Arsenic and chromium from chemically-treated timber.

The risk from such exposures vary depending on how often you do this type of work. 

To reduce your exposure to these chemicals; work in a well ventilated area, and 

work with approved safety equipment, such as those dust masks that are specifically 

designed to filter out microscopic particles.

Always wear eye protection and a dust mask for dusty applications and when drilling/

chiselling overhead. Sanding particles can be absorbed by your eyes and inhaled 

easily and may cause health complications.

Special requirements:

•  Wear ear protectors. Exposure to noise can cause hearing loss.
•   Use auxiliary handles supplied with the tool. Loss of control can cause personal 

injury.

ROTARY HAMMER DRILL SAFETY WARNINGS

 

WARNING! 

When using mains-powered tools, basic safety precautions, including the 

following, should always be followed to reduce risk of fire, electric shock, personal injury 

and material damage. 

Read the whole manual carefully and make sure you know how to switch the tool off in an emergency, 

 

before operating the tool. 
Save these instructions and other documents supplied with this tool for future reference.
The electric motor has been designed for 230V and 240V only. Always check that the power supply 

corresponds to the voltage on the rating plate.
Note: The supply of 230V and 240V on Ozito tools are interchangeable for Australia and New Zealand.

This tool is double insulated therefore no earth wire is required.

If the supply cord is damaged, it must be replaced by an electrician or a power tool repairer in order to avoid 

a hazard.

Note:

 Double insulation does not take the place of normal safety precautions when operating this tool. The 

insulation system is for added protection against injury resulting from a possible electrical insulation failure 

within the tool.

Using an Extension Lead

Always use an approved extension lead suitable for the power input of this tool. Before use, inspect the 

extension lead for signs of damage, wear and ageing. Replace the extension lead if damaged or defective.
When using an extension lead on a reel, always unwind the lead completely. Use of an extension lead not 

suitable for the power input of the tool or which is damaged or defective may result in a risk of fire and electric 

shock.

WARNING!

 

Read all safety warnings and all instructions. 

Failure to follow the warnings and 

instructions may result in electric shock, fire and/or serious injury. 

 

Save all warnings and instructions for future reference. The term “power tool” in the 

warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power 

tool.

1. Work area safety 

a.  

 Keep work area clean and well lit

. Cluttered or dark areas invite accidents. 

b.  

 Do not operate power tools in explosive atmospheres, such as in the presence of flammable 

liquids, gases or dust.

 Power tools create sparks  

which may ignite the dust or fumes. 

c.  

 Keep children and bystanders away while operating a power tool.

 Distractions can cause you to 

lose control.

2. Electrical safety 

a.  

 Power tool plugs must match the outlet. Never modify the plug in any way.  

Do not use any adapter plugs with earthed (grounded) power tools.

 Unmodified plugs and matching 

outlets will reduce risk of electric shock. 

b.    

Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and 

refrigerators. 

There is an increased risk of electric shock  

if your body is earthed or grounded. 

c.    

Do not expose power tools to rain or wet conditions.

 Water entering a power tool will increase the 

risk of electric shock. 

d.  

 Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. 

Keep cord away from heat, oil, sharp edges or moving parts.

 Damaged or entangled cords increase 

the risk of electric shock. 

e.    

When operating a power tool outdoors, use an extension cord suitable  

for outdoor use.

 Use of a cord suitable for outdoor use reduces the risk of electric shock. 

f.  

 If operating a power tool in a damp location is unavoidable, use a residual current device (RCD) 

protected supply.

 Use of an RCD reduces the risk of electric shock. 

3. Personal safety 

a.  

 Stay alert, watch what you are doing and use common sense when operating a power tool. Do 

not use a power tool while you are tired or under the influence of drugs, alcohol or medication.

 A 

moment of inattention while operating power tools may result in serious personal injury. 

b.  

Use personal protective equipment. Always wear eye protection.

 Protective equipment such as dust 

mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce 

personal injuries. 

c.  

 Prevent unintentional starting. Ensure the switch is in the off-position before connecting to 

power source and/or battery pack, picking up or carrying the tool. 

Carrying power tools with your 

finger on the switch or energising power tools that have the switch on invites accidents. 

d.    

Remove any adjusting key or wrench before turning the power tool on.

  

A wrench or a key left attached to a rotating part of the power tool may result  

in personal injury. 

e.    

Do not overreach. Keep proper footing and balance at all times.

 This enables better control of the 

power tool in unexpected situations. 

f.  

 Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves away 

from moving parts.

 Loose clothes, jewellery or long hair can be caught in moving parts.

g.    

If devices are provided for the connection of dust extraction and collection facilities, ensure 

these are connected and properly used.

 Use of dust collection can reduce dust-related hazards.

4. Power tool use and care 

a.  

 Do not force the power tool. Use the correct power tool for your application. 

The correct power tool 

will do the job better and safer at the rate for which it was designed. 

b.    

Do not use the power tool if the switch does not turn it on and off.

 Any power tool that cannot be 

controlled with the switch is dangerous and must be repaired. 

c.  

 Disconnect the plug from the power source and/or the battery pack from the power tool before 

making any adjustments, changing accessories, or storing power tools.

 Such preventive safety 

measures reduce the risk of starting the power tool accidentally. 

d.    

Store idle power tools out of the reach of children and do not allow persons unfamiliar with the 

power tool or these instructions to operate the power tool.

 Power tools are dangerous in the hands 

of untrained users. 

e.    

Maintain power tools. Check for misalignment or binding of moving parts, breakage of parts and 

any other condition that may affect the power tool’s operation. If damaged, have the power tool 

repaired before use.

 Many accidents are caused by poorly maintained power tools. 

f.  

 Keep cutting tools sharp and clean.

 Properly maintained cutting tools with sharp cutting edges are 

less likely to bind and are easier to control. 

g.    

Use the power tool, accessories and tool bits etc. in accordance with these instructions, taking 

into account the working conditions and the work to be performed. 

Use of the power tool for 

operations different from those intended could result in a hazardous situation. 

5. Service 

a.  

 Have your power tool serviced by a qualified repair person using only identical replacement 

parts. 

This will ensure that the safety of the power tool  

is maintained.  

GENERAL POWER TOOL SAFETY WARNINGS

ELECTRICAL SAFETY

Summary of Contents for RHD-900

Page 1: ...or resulting from abuse accidents or alterations Failure to perform maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS Y...

Page 2: ...SDS Flat Chisel 14 x 250mm 13 1 x SDS Point Chisel 14 x 250mm 14 Dust Cover 15 High Temperature Grease 16 Pin Spanner ACCESSORIES SETUP PREPARATION WARNING ENSURE THE TOOL IS DISCONNECTED FROM THE POWER SUPPLY BEFORE PERFORMING ANY OF THE FOLLOWING OPERATIONS Required Drilling Depth 1 Loosen the depth rod securing nut then insert depth rod 4 Drill the hole until the end of the depth rod touches th...

Page 3: ... and hold 5 Rotate and continue to insert as far as possible 7 Checked SDS accessory is locked Try to pull it out Note It should have approx 10 20mm movement This is normal 2 Prior to insertion into drill add supplied lubricant to the SDS accessory 4 Insert SDS Accessory 6 Release locking sleeve 8 To remove the SDS accessory pull back the locking sleeve and pull accessory out a b Accessory SDS The...

Page 4: ...mode selector to the hammer icon and rotate the rear mode selector to the drill and hammer icon This setting is recommended for use when you desire a hammer action without the accessory rotating which is ideal for chiselling or chipping away at masonry products pick or chisel accessory bits should be used Note In chiselling mode the drill bit is fixed in position and cannot be rotated Drilling Rot...

Page 5: ...Brushes When the carbon brushes wear out the drill will spark and or stop Discontinue use as soon as this happens They should be replaced prior to recommencing use of the drill Carbon brushes are a wearing component of the drill therefore not covered under warranty Continuing to use the drill when carbon brushes need to be replaced may cause permanent damage to the drill Carbon brushes will wear o...

Page 6: ...ety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference The term power tool in the warnings refers to your mains operated corded power tool or battery operated cordless power tool 1 Work area safety a Keep work area clean and well lit Cluttered or dark areas inv...

Reviews: