3. INSTALLATION
Connecting the Discharge Outlet
1. Insert a hose
adaptor and an
O-ring into one of
the collars.
2. Screw the hose adaptor and
collar tightly onto the pump
outlet in a clockwise direction
to secure in place.
Note:
Teflon tape (not supplied)
is recommended on threads to
ensure a water tight seal and
prevent any leakage. DO NOT
use adhesives in replace of
Teflon tape.
The outlet allows for a 25.4mm (1”) pipe to be connected and is
capable of a maximum head of 9.5m.
2. CONNECTING THE OUTLET
IMPORTANT:
TO USE THE PUMP IN PERMANENT
INSTALLATIONS WITH RIGID PIPES, INSTALL A NON-RETURN
VALVE TO AVOID THE FLUID BEING RE-CIRCULATED ONCE
THE PUMP HAS STOPPED.
WARNING!:
ALL CONNECTIONS MUST BE AIR TIGHT,
FAILURE TO DO SO MAY RESULT IN AN AIR LEAK
WHICH CAN PREVENT THE PUMP FROM PRIMING.
1. Ensure the pump is mounted to a rigid base or ground.
9.5m
7m
MAXIMUM DELIVERY HEIGHT
WATER LEVEL
WARNING!:
ALWAYS CARRY OR LIFT THE PUMP BY THE
CARRY HANDLE TO AVOID DAMAGING THE UNIT.
WARNING!:
THIS PRODUCT IS INTENDED FOR PUMPING
WATER IN A HOME DOMESTIC APPLICATION. DO NOT
USE IT FOR CORROSIVE, ABRASIVE, EXPLOSIVE OR
DANGEROUS LIQUIDS.
2. Ensure the distance from the surface of the water to the
pump inlet does not exceed 7m.
3. Ensure the distance from the pump to the highest point that
you wish to deliver the water does not exceed 9.5 metres.
Before starting, perform a few simple checks:
WARNING!:
ENSURE THE OUTLET FOR THIS
PUMP, INCLUDING ANY HOSES OR PIPES ARE NOT
RESTRICTED OR OBSTRUCTED IN ANY WAY. TAPS,
VALVES AND ANY TYPE OF TRIGGER NOZZLE MUST
NEVER BE USED WITH THIS PUMP. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PUMP
FAILURE OR SERIOUS INJURY.