TEMPERATURE & SAFETY PROTECTION: 

• 

INTERNAL OVERHEAT PROTECTION: 

The charger has a built-in overheat and an overload 

electronic circuit. This protects the charger from being damaged if overheated or overloaded 
and will automatically decrease the charging current. Once the units internal temperature 
decreases to a safe level, the charger will resume normal charging. 

• 

SAFETY TIMER PROTECTION: 

The charger has safety timers for every stage. If the battery 

voltage doesn’t reach a certain voltage within a certain time, the unit will stop charging as 
it’s highly likely that you’re attempting to charge a severely discharged or heavily sulphated 
battery. If any of the stages time out, the charger will immediately stop charging in order to 
protect the battery. This will be indicated  with the fault LED flashing slowly. 

• 

REVERSE POLARITY: 

The charger has reverse polarity protection. If the charger output leads 

are connected reverse polarity, the fault LED will come on and the charger will be disabled. 
Simply unplug  the charger from AC power and then connect the output leads to the correct 
polarity.

• 

SHORT CIRCUIT PROTECTION: 

The charger will automatically turn off if the output leads are 

short circuited and the fault LED will come on. This prevents the charger from being damaged 
if the positive and negative crocodile clips or the optional ring terminals accidentally touch each 
other while the charger is turned on.

• 

ECO MODE: 

This Oz Charge battery charger has a built in ultra low power consumption 

circuit. If AC power is connected and the battery is disconnected, after 10 seconds the charger 
will automatically go into an ECO mode. During this mode the power drawn is less than 0.36W 
which totals 0.01kWh per day power consumption. If AC power is connected and the battery 
is connected, once the battery is fully charged and during the long term maintenance stage, 
the total power consumption is around 0.03kWh per day. 

 Both the selected Charge rate and Battery type LED’s will flash GREEN to indicate ECO mode. 

BATTERY TYPES & CAPACITY:

• 

Suits 12V conventional lead acid batteries (VRLA) Gel, Calcium SMF, AGM, WET, EFB and 

compatible 

Lithium-ion (including LiFePO4) batteries

• 

The Ah (Ampere-hour) capacities shown below are to be used as a general guide only.

Some batteries may be able to handle a higher charge current. Refer to the battery 
manufacturers specifications and recommendations for your charging requirements. 

OC-PRO600L

OC-PRO1200L

Charge Rate:

1A

4A

6A

1A

8A

12A

Charging

3 - 20Ah

(150CCA)

12 - 80Ah 

(600CCA)

18 - 120Ah 

(900CCA)

3 - 20Ah

(150CCA)

24 - 160Ah

(1200CCA)

36 - 240Ah

(1700CCA)

Maintaining

< 100Ah

(725CCA)

< 120Ah

(900CCA)

< 180Ah

(1300CCA)

< 100Ah

(725CCA)

< 240Ah

(1700CCA)

<360Ah

(2600CCA)

Summary of Contents for OC-PRO1200L

Page 1: ...OWNER S MANUAL Model OC1206U OC1212U AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED OWNER S MANUAL Models OC PRO600L OC PRO1200L AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED...

Page 2: ...d by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard If battery acid contacts your skin or clothing wash immediately with soap and water If acid enters you...

Page 3: ...he battery It also depends on whether the battery is still connected in the vehicle Can be left on 24 7 to ensure your battery is always maintained and fully charged The battery charger can be left un...

Page 4: ...nd the fault LED will come on Thispreventsthechargerfrombeingdamaged ifthepositiveandnegativecrocodileclipsortheoptionalringterminalsaccidentallytoucheach otherwhilethechargeristurnedon ECO MODE This...

Page 5: ...acid type batteries only 13 6V lead acid type batteries only StartVoltage 2V 2V OperatingTemperature 15 to 50 C 15 to 50 C StorageTemperature 25 to 85 C 25 to 85 C Operating Humidity 90 RH Max 90 RH...

Page 6: ...f the Fault Indicator LED illuminates Red please check your connections as it s likely that the Positive and Negative Leads are reversed If the Battery is out of the vehicle ConnecttheRed Orange Croco...

Page 7: ...Flash Gently charges the battery using a reduced charge output until the battery voltages reaches 11V If the battery voltage doesn t reach 11V within 6 hours the safety timer protection will stop the...

Page 8: ...without overcharging the battery 5 Absorption Charging Stage 2 Blue Charging LED ON and Green Full LED Flashing Steps up the constant voltage to 14 4V while reducing the charging output current to ens...

Page 9: ...el Calcium AGM WET Battery type selection only Double Flash OFF ON ON ON Soft Start Charging Time Out Error Single Flash OFF ON ON Flash Bulk Charging Time Out Error ON OFF ON ON Flash Reverse Polarit...

Page 10: ...9 Oz Charge manual www ozcharge com au CHARGING CURVE...

Page 11: ...attery may need replacement Move battery charger to a cooler environment The full float light won t come on Fault Red LED is Flashing or Full Green LED is Flashing Charging LED is ON Flashing with Fau...

Page 12: ...der warranty the customer should enclose a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as OzCharge Australia Pty Ltd Oz Charge accep...

Reviews: